The transmission level for each baud rate and speed follows the service data.
5.5.4.5 Faculty Test
5.5.4.5.1 FACULTY Tests
The faculty tests are selected by pressing the numeric key 6 from the test mode menu.
These tests test the following faculties of this fax.
Test type
Sensor tests
Operation panel test
Line signal reception test
5.5.4.5.2 Sensor Tests
The sensor test is selected by pressing the numeric key 3 from the faculty test menu. In this test, you can check the status of each sensor of this fax in items 1 to 4
on the display.
You can also check if sensors that use actuators and microswitches are operating correctly by moving the actuator or microswitch.
Cursor key
Overview
Test whether the sensors are operating correctly.
Tests whether the button switches on the control panel are operating
correctly.
Tests whether the NCU board signal sensor and frequency counter are
operating correctly.
6-3 SENSOR
[1 ] - - - [ 4 ]
Pressing the 1 key
CRG of
FCV on
ALS [ON of of of of]
CRG
: Cartridge sensor on/of
FCV
: Front cover switch on/of
ALS
: Cassette recording paper sensor/Manual paper feed sensor
/Top sensor/Paper delivery sensor/Paper full sensor on/of