G3 Signal Transmission Test; Aging Test; Faculty (Function) Test (6: Faculty Test) - Canon PC1000s Service Manual

Table of Contents

Advertisement

CHAPTER 2 USING THE MACHINE
3.20.7 AG lNG Test
(5:
AGING TEST)
Not used.
3.20.8 FACULTY (function) Test (6: FACULTY TEST)
A press on
'6'
on the keypad from the TEST
MODE
menu selects the FACULTY test. A
press on the keypad (1 through
7,9,
#)
during the test will bring up the following menu:
Keypad
Item
Description
G3 Signal Transmission Test
not used
Sensor Test
ADF Test
not used
Speaker Test
Control Panel Test
Live Connection Reception Test
ESS Test
Transmits a G3 signal at
4800
bps to the telephone
line and the speaker.
Executes an operation test on a specific sensor.
Executes an operation test on the ADF.
Executes an operation test on the speaker.
Executes an operation test on the LCD/LED/control
panel keys.
Executes an operation test on the signal sensor on
the NCU board and the frequency counter.
Executes an operation test on the
ESS
function.
G3 Signal Transmission Test (6-1: G3 4800 bps Tx)
A press on '1' on the keypad on the FACULTY TEST menu selects the G3 transmission
test. In this test, a G3 signal is transmitted using the telephone line terminal and the speaker at
4800 bps.
Sensor Test (6-3: SENSOR)
This mode is used to check the state of a specific sensor of the machine on the LCD. A
press on '3' on the keypad from the FACULTY TEST menu selects the sensor test. The LCD
indication changes as the sensor goes ON and OFF.
The paper leading edge sensor (PS102). LGL paper sensor (PSlOl), and de-
livery sensor (PS3) cannot be checked by running a sensor test.