AMT Datasouth AMTACCEL-5350 User Manual page 191

Amt datasouth printer user's guide amtaccel-5350
Table of Contents

Advertisement

Table D-3. AMT and Diablo 630 Escape Sequences––continued
Function
Set font ...............................
Courier ...........................
Courier (alternate) .........
Gothic, 12 cpi ................
Gothic, 12 cpi (alternate)
Gothic, 17.1 cpi .............
Gothic, 17.1 cpi (alt.) ....
Trend PS ........................
Trend PS (alternate) .......
Elite ...............................
Orator ............................
Courier Legal ................
Broadway .......................
Micro ..............................
Script ..............................
Gothic PS .......................
Micro PS ........................
OCR-A ...........................
OCR-B ...........................
APL ................................
General Scientific ...........
DEC Scientific ...............
Chemical ........................
Download font 1 ............
Download font 2 ............
End extended character ....
set mode
ASCII
Hexadecimal
Text Functions––continued
ESC @ F n
1B 40 46 n
ESC @ F SOH
1B 40 46 01
ESC @ F 1
1B 40 46 31
ESC @ F STX
1B 40 46 02
ESC @ F 2
1B 40 46 32
ESC @ F ETX
1B 40 46 03
ESC @ F 3
1B 40 46 33
ESC @ F EOT
1B 40 46 04
ESC @ F 4
1B 40 46 34
ESC @ F ENQ
1B 40 46 05
ESC @ F BEL
1B 40 46 07
ESC @ F HT
1B 40 46 09
ESC @ F FS
1B 40 46 1C
ESC @ F RS
1B 40 46 1E
ESC @ F NAK
1B 40 46 15
ESC @ F ACK
1B 40 46 06
ESC @ F '
1B 40 46 27
ESC @ F SP
1B 40 46 20
ESC @ F ETB
1B 40 46 17
ESC @ F EM
1B 40 46 19
ESC @ F LF
1B 40 46 0A
ESC @ F VT
1B 40 46 0B
ESC @ F CAN
1B 40 46 18
ESC @ F 255
1B 40 46 FF
ESC @ F 254
1B 40 46 FE
ESC @ C
1B 40 43
Decimal
27 64 70 n
This sequence selects any available font; it does not
change the current character spacing. Each font is
27 64 70 1
assigned one or more numbers. To select a font, the
sequence must specify one of the assigned numbers.
27 64 70 49
Downloaded fonts are assigned numbers in reverse order
beginning with FF hex (255 decimal). The list of
27 64 70 2
sequences to the left is only a partial list of font
27 64 70 50
selections.
27 64 70 3
27 64 70 51
When the printer receives a sequence that selects a font
27 64 70 4
that is not in the installed Intelli-card(s), it sounds the
27 64 70 52
audible alarm, displays the message FONT
UNAVAILABLE on the control panel, and continues
27 64 70 5
printing.
27 64 70 7
27 64 70 9
27 64 70 28
27 64 70 30
27 64 70 21
27 64 70 6
27 64 70 39
27 64 70 32
27 64 70 23
27 64 70 25
27 64 70 10
27 64 70 11
27 64 70 24
27 64 70 255
27 64 70 254
27 64 67
This sequence ends the ECS mode by replacing the ECS
characters in the active font with the normal ASCII/IBM
characters designated by the SETS parameter on the
printer's Setup menu. ECS characters are assigned codes
above 7F hex. To restart the ECS mode, select the font
again using the Set Font sequence. If the active font is not
an ECS font, the printer ignores this sequence.
User's Guide
Description
Code Sets D-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amt accel-5350

Table of Contents