AMT Datasouth AMTACCEL-5350 User Manual page 184

Amt datasouth printer user's guide amtaccel-5350
Table of Contents

Advertisement

User's Guide
Table D-2. AMT and Diablo 630 Control Codes––continued
Function
Enable characters with .....
codes outside normal range
(continued)
Disable characters with .....
codes outside normal range
Print character with ..........
code above 7F hex
Escape ................................
Print character with ..........
code below 20 hex
Space ..................................
Delete ..................................
D-6 Code Sets
ASCII
Hexadecimal
SO
0E
SI
0F
EM
19
ESC
1B
GS
1D
SP
20
DEL
7F
Decimal
14
If an ECS font is active and 8-bit data is in use, this code
permits the printing of characters with codes from 80 to
9F hex. An SI code cancels this function.
If an ECS font is active and 7-bit data is in use, this code
permits the printing of characters with codes above 7F
hex. After receiving an SO code, the printer adds 80 hex
to all subsequent codes it receives and prints the result-
ing characters. An SI code cancels this function.
15
This code causes one of the following actions:
If an ECS font is active and 8-bit data is in use, this code
cancels the printing of characters with codes from 80 to
9F hex. After receiving an SI code, the printer prints
spaces for these codes.
If an ECS font is active and 7-bit data is in use, this code
cancels the printing of characters with codes above
7F hex.
25
If an ECS font is not active and 7-bit data is in use, this
code permits the printing of a character with a code above
7F hex. When the printer receives an EM code, it adds
80 hex to the next code it receives and prints the resulting
character. This function affects only the next code in the
data stream.
27
This code begins an escape sequence.
29
If an ECS font is not active, this code permits the printing
of a character with a code below 20 hex. After receiving
a GS code, the printer does not perform the normal control
function for the next code it receives, but instead prints the
assigned character. This function affects only the next code
in the data stream.
32
This code moves the current print position one character
space to the right.
127
The printer ignores this code unless the code is used within
an escape sequence.