Environmental Specifications; Power Specifications - Cisco UCS C210 Installation And Service Manual

Generations m1 and m2
Hide thumbs Also See for UCS C210:
Table of Contents

Advertisement

Environmental Specifications

Table A-2
Table A-2
Description
Temperature, operating:
Derate 1°C for every 1000 ft (304 m) up to a
maximum altitude of 10,000 ft (3048 m).
Temperature, nonoperating
within altitude: 0 to 40,000 feet (0 to 12,000
meters)
Humidity (RH), noncondensing
Altitude
Sound power level
Measure A-weighted per ISO7779 LwAd (dBA)
Operation at 73°F (23°C)
Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)

Power Specifications

Table A-3
Table A-3
Description
AC-input voltage
AC-input frequency
Maximum AC-input current
Maximum output power for each power
supply
Power supply output voltage
You can get more specific power information for your exact server configuration by using the Cisco UCS
Power Calculator:
http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/
Cisco UCS C210 Server Installation and Service Guide
A-2
lists the environmental specifications for the server.
Environmental Specifications
lists the specifications for each power supply (Cisco part number R2X0-PSU2-650W).
Power Supply Specifications
Specification
50 to 95°F (10 to 35°C)
–40 to 149°F (–40 to 65°C)
5 to 93%
0 to 10000 feet
65.5 dBA
6.8 Bels
Specification
115 to 230 VAC nominal
(Range: 90 to 264 VAC)
50 to 60 Hz nominal
(Range: 47 to 63 Hz)
10 Amps
650 W (up to two power supplies can be installed)
Main power: 12 VDC
Standby power: 5 VDC
Appendix
OL-20887-02