Chapter 8: Postinstallation administration

Enabling alarms to INADS by way of the SNMP module

Note:
Perform this procedure only if the installation includes a Secure Service Gateway
Note:
(SSG).
To enable alarms on the media servers:
1. Start a Telnet session on the media server.
2. Type almsnmpconf -d ipaddress -c communityname and press Enter, where
ipaddress is the trap receiver address for the SSG device and communityname is the
community string name that the SSG device requires.
3. Type almsnmpconf and press Enter and verify that the correct information is entered.
4. Type almenable -s y and press Enter.
5. Type almenable and press Enter and verify that alarm origination is enabled on the
SNMP module. If used, also verify that alarm origination by way of a modem is still
enabled.
6. Log off.

Before leaving the site

Provide the default LAN security settings to the customer.
Ensure that the customer knows that remote access to the media server is available only if
the following services are enabled on the Maintenance Web Interface Firewall screen:
- telnet must be enabled to access Telnet
- https must be enabled to access the Maintenance Web Interface
- def-sat must be enabled to access the SAT commands
- 162/udp must be enabled to receive SNMP traps from the UPS and the Avaya
Ethernet switch