Default Ip Addresses For The Ups; Preparing To Configure The Snmp Module - Avaya S8500 Installing And Configuring

Media server
Hide thumbs Also See for S8500:
Table of Contents

Advertisement

Chapter 2: SNMP Configuration

Default IP addresses for the UPS

The following table shows the default IP addresses for the UPS.
For how to administer the SNMP module in the UPS, see
page 37.

Preparing to configure the SNMP module

Before you configure the SNMP module, you must complete the following prerequisites:
Your Services laptop computer is plugged into the correct administration port on the SNMP
module.
The UPS is plugged into a nonswitched electrical outlet.
The communication protocol on your computer has the following port settings so that you
can use your terminal emulation program:
- 9600 baud
- No parity
- 8 data bits
- 1 stop bit
- No flow control
Note:
Avaya Terminal Emulation and HyperTerminal are supported terminal emulation
Note:
applications.
If a Network Management System (NMS) is to monitor the UPS, you coordinated the
assignment of community names with the network administrator. If an NMS is not used,
you set the community names to unique string values.
36
Installing and Configuring the Avaya S8500 Media Server
IP address for the UPS
Subnet mask for the UPS
Gateway address for the UPS
IP address for the
trap receiver (media server)
198.152.254.239
255.255.255.0
198.152.254.201