Re-Entering The Server Serial Number And Product Id; System Battery - HP ProLiant DL585 Generation 2 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL585 Generation 2:
Table of Contents

Advertisement

Slide the system board out through the back of the server.
12.
IMPORTANT:
serial number through RBSU
58).
To replace the component, reverse the removal procedure.

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the server serial number and the product ID.
During the server startup sequence, press the F9 key to access RBSU.
1.
Select the Advanced Options menu.
2.
Select Serial Number. The following warning is displayed:
3.
Warning: The serial number should ONLY be modified by qualified service
personnel. This value should always match the serial number located on
the chassis.
Press the Enter key to clear the warning.
4.
Enter the serial number.
5.
Select Product ID. The following warning is displayed.
6.
Warning: The Product ID should ONLY be modified by qualified service
personnel. This value should always match the Product ID located on the
chassis.
Enter the product ID and press the Enter key.
7.
Press the Escape key to close the menu.
8.
Press the Escape key to exit RBSU.
9.
Press the F10 key to confirm exiting RBSU. The server will automatically reboot.
10.

System battery

If replacing the system board or clearing NVRAM, you must re-enter the server
("Re-entering the server serial number and product
ID" on page
Removal and replacement procedures 58