Power down the server (on page 26).
1.
Extend the server from the rack
2.
Remove the access panel
3.
CAUTION:
Disconnect the cable from the cache module only if the battery pack is not being
used to recover data from the server or transfer data to another server.
If the existing cache is connected to a battery, observe the BBWC Status LED
4.
page 80).
If the LED is blinking every 2 seconds, data is still trapped in the cache. Restore system power,
o
and repeat the previous steps.
If the LED is not lit, disconnect the battery cable from the cache.
o
Remove the controller.
5.
("Extending the server from the
("Removing the access
panel" on page 28).
rack" on page 27).
("Battery pack
Removal and replacement procedures 52