Re-Entering The Server Serial Number And Product Id - HP HPE ProLiant DL325 Maintenance And Service Manual

Table of Contents

Advertisement

5.
Install all the components removed from the system board.
6.
Install the access panel.
7.
Install the server into the rack.
8.
Connect each power cord to the server.
9.
Connect each power cord to the power source.
10. Power up the server.
11. If removed, install the front bezel.
12. Ensure all firmware, including option cards and embedded devices, is updated to the same versions to ensure that
the latest drivers are being used.
13. Re-enter any Secure Boot Keys that were previously added in the Secure Boot configuration.
14. Re-enter the server serial number and the product ID.

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the server serial number and the product ID.
Procedure
1. During the server startup sequence, press the F9 key to access UEFI System Utilities.
2. Select System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options > Advanced System
ROM Options > Serial Number, and then press the Enter key.
3. Enter the serial number and press the Enter key.
The following message appears:
The serial number should only be modified by qualified service personnel.
This value should always match the serial number located on the chassis.
4. To clear the warning, press the Enter key.
5. Enter the serial number and press the Enter key.
Removal and replacement procedures
102