Fujitsu SPARC Enterprise M3000 Xscf Reference Manual page 525

For xcp version 1110
Hide thumbs Also See for SPARC Enterprise M3000:
Table of Contents

Advertisement

Performs an initial diagnosis of PSB#01 with detailed messages displayed.
EXAMPLE 2
XSCF> testsb -v 1
Initial diagnosis is about to start. Continue? [y|n] :y
SB#01 powered on sequence started.
:
:
:
Initial diagnosis has completed.
{0} ok SB power off sequence started. [1200sec]
0.end
SB powered off.
XSB
Test
Fault
---- ------- --------
01-0 Passed
Normal
Performs the initial diagnosis on all the PSB that are mounted.
EXAMPLE 3
XSCF> testsb -c all
Initial diagnosis is about to start. Continue? [y|n] :y
SB power on sequence started.
0end
Initial diagnosis started. [1800sec]
0..... 30..... 60..... 90.....120end
Initial diagnosis has completed.
SB power off sequence started. [1200sec]
0.end
SB powered off.
XSB
Test
Fault
---- ------- --------
00-0 Passed
Normal
01-0 Passed
Normal
02-0 Passed
Normal
03-0 Passed
Normal
Ignores the settings for the warm-up time of the system and the wait time
EXAMPLE 4
before system startup to perform the initial diagnosis on the PSB that are
mounted.
XSCF> testsb -c all
Initial diagnosis is about to start. Continue? [y|n] :y
Ignore warmup-time and air-conditioner-wait-time, Continue?[y|n] :y
SB power on sequence started.
0end
Initial diagnosis started. [1800sec]
0..... 30..... 60..... 90.....120end
Initial diagnosis has completed.
testsb(8)
System Administration
511