Configuring the Data Link Layer Protocol for E1, T1, and Serial Interfaces
Quick Start
N o t e
N o t e
6-76
Together, the frame-relay bc command and the frame-relay be command
define the amount of bandwidth you can use on the Frame Relay link. The sum
of the values you specify for these two settings should be greater than 8000.
10. Bind the physical interface—the E1, T1, or serial interface—to the Frame
Relay interface. From the global configuration mode context, enter:
Syntax: bind <number> <physical interface> <slot> /<port> [<tdm-group
number>] <logical interface> <logical interface number>
For example, to bind the E1 1/1 interface to the Frame Relay 1 interface,
enter:
ProCurve(config)# bind 1 e1 1/1 1 fr 1
To bind the serial 1/1 interface to the Frame Relay 1 interface, enter:
ProCurve(config)# bind 1 ser 1/1 fr 1
If you are binding a serial interface to the Frame Relay interface, you do not
include the TDM group number because you do not use TDM groups on a serial
interface.
11. View the status of the Frame Relay interface and subinterface. From the
enable mode context, enter:
ProCurve# show interface fr 1
ProCurve# show interface fr 1.103

HDLC

To configure HDLC for an E1, T1, or serial interface, complete these steps:
1.
From the global configuration mode context, create an HDLC interface.
Syntax: interface <interface> <number>
ProCurve(config)# interface hdlc 1
2.
Enter the IP address.
Syntax: ip address <A.B.C.D> <subnet mask | /prefix length>
ProCurve(config-hdlc 1)# ip address 10.1.1.1 /24
3.
Activate the HDLC 1 interface
ProCurve(config-hdlc 1)# no shutdown