Terminal Function Selection; Modifying Input Terminal Functions - Toshiba TOSVERT VF-S11 Instruction Manual

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-S11:
Table of Contents

Advertisement

6.3

Terminal function selection

6.3.1
Keeping an input terminal function always active (ON)
: Always-active function selection 1
: Always-active function selection 2
• Function
This parameter specifies an input terminal function that is always to be kept active (ON).
Parameter setting
Title
Always-active function selection 1
Always-active function selection 2
* Coast stop
The standard default setting is for deceleration stop.
To make a coast stop, assign a "1(ST)" terminal
function to an idle terminal using the programmable
terminal function.
Change to
For coast stop, open the ST-CC when stopping the
motor in the state described at left.The monitor on the
inverter at this time will display
6.3.2

Modifying input terminal functions

: Input terminal selection 1 (F)
: Input terminal selection 2 (R)
: Input terminal selection 3 (RES)
: Input terminal selection 4 (S1)
: Input terminal selection 5 (S2)
: Input terminal selection 6 (S3)
: Input terminal selection 7 (VIB)
: Input terminal selection 8 (VIA)
Function
= .
.
F-7
Adjustment range
0-65 (See K-16)
0-65 (See K-16)
Motor
speed
F-CC
ST-CC
E6581158
Default setting
0 (No function)
1 (Standby)
6
Coast stop
ON
OFF
ON
OFF