Output frequency (Hz)
Parameter setting
Title
Upper limit frequency
Lower limit frequency

5.10 Base frequency

: Base frequency 1
: Base frequency voltage 1
• Function
Sets the base frequency and the base frequency voltage in conformance with load specifications or the
Base frequency.
Note: This is an important parameter that determines the constant torque control area.
Base frequency voltage
Title
Base frequency 1
Base frequency voltage1
Upper limit
frequency
Output frequency (Hz)
0           100%
Frequency setting signal
* Frequencies that go
higher than
will not
be output.
Function
0.5 -
0.0 -
0
Function
50-330 (V) : 240V class
50-660 (V) : 500/600V class
E-17
Lower limit
frequency
0           100%
Frequency setting signal
* The output frequency
cannot be set at less than
.
Adjustment range
(Hz)
(Hz)
Output frequency (Hz)
Adjustment range
Factory default setting
25.0-500.0 (Hz)
E6581158
Factory default
setting
50.0 (WP type)
60.0 (WN, AN type)
0.0
5
50.0 (WP type)
60.0 (WN, AN type)
230 (240V class)
460 (500V class)
575 (600V class)

Advertisement