6.3
Terminal function selection
6.3.1 Keeping an input terminal function always active (ON)
,
• Function
This parameter specifies an input terminal function that is always kept active (ON). (Only one function
selectable)
[Parameter setting]
Title
* The selected function is always kept active regardless of the type of logic (positive or negative) in the table of
function settings in 7.2.1.
6.3.2 Modifying input terminal functions
: Input terminal function selection 1 (F)
: Input terminal function selection 2 (R)
: Input terminal function selection 4 (RES)
: Input terminal function selection 5 (S1)
: Input terminal function selection 6 (S2)
6
⇒ For details, refer to Section 7.2.1.
• Function
Use the above parameters to send signals from an external programmable controller to various control input
terminals to operate and/or set the inverter.
The desired contact input terminal functions can be selected from 120 types (-). This gives system
design flexibility.
Using the SW3 switch, the function of the RR/S4 terminal can be selected between analog input and contact
input. By default, the RR/S4 terminal is set as an analog input terminal (voltage input terminal). To use it as a
contact input terminal, therefore, you need to turn the SW3 switch to the S4 position.
Setting of contact input terminal function
Terminal
symbol
–
–
F
R
RES
S1
S2
S3
The terminal below is operative only when SW3 is in the S4 position.
RR/S4
Note 1: The function that has been selected using , and (always ON function selection 1~3
parameter) are always activated.
Note 2: When using the RR/R4 terminal as a contact input terminal (sink logic), always turn the SW3 slide switch to
the S4 position.
,
: Always ON function selection 1~3
Function
Always ON function selection 1
Always ON function selection 2
Always ON function selection 3
Title
Always ON function selection 1
,
Always ON function selection 2, 3
Input terminal function selection 1 (F)
Input terminal function selection 2 (R)
Input terminal function selection 4 (RES)
Input terminal function selection 5 (S1)
Input terminal function selection 6 (S2)
Input terminal function selection 7 (S3)
Input terminal function selection 7 (S4)
Adjustment range
~
~
~
: Input terminal function selection 7 (S3)
: Input terminal function selection 8
(RR/S4)
~ :
Input terminal function selection 9~16
~ :
Input terminal function selection 17~20
Function
F-6
E6581528
Default setting
Default
Adjustment range
setting
(ST)
(F)
~
(R)
(⇒ Refer to
(RES)
Section 11.)
(S1)
(S2)
(S3)
–
–
~ [Note
(S4)
2]