Toshiba TOSVERT VF-S11 Instruction Manual page 172

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-S11:
Table of Contents

Advertisement

Example of setting 2
When
Each time you press the
(Hz) and also the value displayed on the operation panel changes in steps of 1. Use these settings to hide
decimal fractions and also the value displayed on the operation panel changes in steps of 1. Use these
settings to hide decimal fractions.
6.21.5 Changing the item displayed by default
• Function
Changing the display format while power is on
When the power is on, the standard monitor mode displays the operation frequency (default setting) in the
format of "
6
■ Parameter setting
✩ ✩ ✩ ✩
=1.00 (Hz), and
key, the frequency setting
▲ ▲
: Standard monitor display selection
This parameter specifies display format while power is on.
" or "
". This format can be changed to any other monitor display format by setting
. This new format, however, will not display an assigned prefix such as
Title
Function
Standard monitor display
selection
For more information on the
Manual."
=1:
changes in steps of 1Hz: 0→ 1 → 2 → ... → 60
Adjustment range
0: Operation frequency (Hz/free unit/step)
1: Frequency command (Hz/free unit/step)
2: Output current (%/A)
3: Inverter rated current (A)
4: Inverter load factor (%)
5: Output power (kW)
6: Frequency command after PID control
(Hz/free unit/step)
7: Optional item specified from an external
control unit
option " ," refer to "Communications Function Instruction
F-78
E6581158
or
.
Default setting
0