Toshiba TOSVERT VF-S11 Instruction Manual page 129

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-S11:
Table of Contents

Advertisement

Title
Function
Auto-restart control
selection
*
If the motor is restarted in retry mode, this function will operate, regardless of the setting of this parameter.
1) Auto-restart after momentary power failure (Auto-restart function)
Input voltage
Motor speed
F-CC
Setting
to
, ( ): This function operates after power has been restored following detection of an
undervoltage by the main circuits and control power.
2) Restarting motor during coasting (Motor speed search function)
Motor speed
F-CC
ST-CC
Setting
to
 o r
first and then connected again.
Note:
The terminal function ST needs to be assigned to an input terminal, using the parameters
.
Adjustment range
0: Disabled
1: At auto-restart after momentary stop
2: When turning ST-CC on or off
3: At auto-restart or when turning ST-CC on or off
4: At start-up
: This function operates after the ST-CC terminal connection has been opened
F-35
E6581158
Default setting
0
ON
OFF
6
ON
OFF
ON
OFF
to

Advertisement