16
When a 911 call is being made from a user station, the 911
ALERT flexible button rapidly flashes on the Attendant station,
and an audible tone emits from the Attendant's speaker. The
display shows:
To turn off the alert:
Press the 911 ALERT flexible button.
Display and tone continues until this occurs, then the
display returns to normal and the audible alarm ceases.
LED continues to flash until all 911 calls are viewed. If
more than one 911 call is logged, press the 911 ALERT
flexible button to advance to view each call in the log.
After all calls are reviewed, 911 ALERT flexible button
lights solid red. All 911 calls are logged on the
Attendant station until they are deleted.
To delete logged 911 alert messages:
1. Press the 911 ALERT flexible button to display the 911 call
you want to delete.
2. Press FLASH to delete that message.

Attendant Clear Alarm

The attendant can dial feature code [606] to clear any alarm. It
does not clear the condition, just clears the display.
E911 CALL
MMM DD Y Y
Dialing 911 from any station overrides previously
enabled features such as
Do Not Disturb.
Attendant Features