Updating BX600 System Components
Ê Extract the firmware file (*.bix) to the root directory of the TFTP file system.
For information on the image file names, see the readme file of the update
package.
Ê Start an Internet browser on the client server. Enter the IP address specified
above in the address field. Enter the user name and password admin. The
home page is displayed.
Ê In the navigation bar choose Flash/File.
I
Only two operation code image files can be stored on the switch blade. If
there are already two image files stored, you must remove at least one of
them before updating the firmware. It is recommended that you remove
the older file (i.e. the file with the lower number).
Ê Expand the File Name list (red arrow) in the Remove Operation Code Image File
section to check if there are already two image files stored on the switch
blade. If so, select the older one in the File Name list and click Remove File.
Figure 25: Removing an operation code image file
Ê Enter TFTP Server IP Address, Source File Name (*.bix) and Destination File
Name.
66
Preparation for Use and Operation
PRIMERGY BX600 S2 Basic Unit