Installing the Hardware
Ê Repeat the procedure with the second support bracket.
Note that the second bracket will be mounted level with the upper edge of
the first support bracket mounted (see
Figure 7: Mounting the left carrier rail
Ê Undo the six screws (1) for adjusting the rail length and place the guide lugs
(a) in the corresponding holes of the support brackets.
Ê Place three plug washers (3) in the appropriate holes of the support brackets
and, while holding the rail in place, fasten it with three screws.
Ê Place two plug washers in the holes of the front left support upright at the
marked attachment points, adjust the rail length (2) and, while holding the
rail in place, fasten it with three screws (4).
Ê Pull the carrier rail of the rack-mounting kit forward as far as possible in the
direction of the arrow (2).
Ê Fasten the six screws for adjusting the rail length (1).
Ê Repeat the procedure for the second rail. Note that for this rail no support
bracket is necessary.
PRIMERGY BX600 S2 Basic Unit
Installing the System in the Rack
figure 6 on page
38).
39