Management Blade Configuration - Fujitsu PRIMERGY BX600 S2 Operating Manual

Fujitsu server user manual
Table of Contents

Advertisement

Preparation for Use and Operation
5.3

Management Blade Configuration

The two redundant management blades provide functionality for remote control
of the PRIMERGY BX600 S2 base unit over the LAN (see
"Management Blade" on page 125
Systems: RemoteView Management Blade - User Interface
manual). To commission the base unit, the LAN parameters of the management
blades must be set using a local client computer.
To configure the management blade, follow the steps listed below.
Pre-Configuration Requirements
The procedures that follow assume that the basic unit is connected to the power
line.
Cabling the System
Ê Connect the serial interface of the client (COM1) to the serial interface of the
master management blade using an RS232 cable (null modem cable).
I
The master management blade is indicated by a green LED (see
section "Control and Connection Panel" on page
Initial Configuration via Serial Connection to Client
Ê Open a HyperTerminal session from the client to the master management
blade. Use the following settings:
Bits per second
Data bits
Parity
Stop bit
Flow control
Terminal type
PRIMERGY BX600 S2 Basic Unit
Management Blade Configuration
and the
„PRIMERGY BX Blade Server
115200
8
None
1
None
VT100
chapter
Description"
126).