Fujitsu PRIMERGY BX600 S2 Operating Manual page 146

Fujitsu server user manual
Table of Contents

Advertisement

Power Supply Units
V
CAUTION!
Because of chassis airflow disruption, the power supply unit slot should
not be vacant and/or uncovered for more than five minutes when the
system power is ON. Exceeding the five-minute limit may damage
components.
All unoccupied PSU slots in the blade server system are fitted with PSU dummy
modules
(figure
94) to ensure that the electromagnetic emission properties of
the system are observed and that the system components are properly cooled.
Each PSU dummy module includes three fans respectively.
There is one LED indicator (1 on
module for monitoring the status of built-in fans.
Figure 94: PSU dummy module
If you want to install an additional power supply unit, you must first remove the
PSU dummy module from the corresponding slot.
Ê Remove the PSU dummy module from the corresponding slot.
Removal/installation is the same as for the power supply unit (see
"Replacing a Power Supply Unit" on page
146
figure
94) on the front of the PSU dummy
142).
PRIMERGY BX600 S2 Basic Unit
Power Supply Concept
1
section

Advertisement

Table of Contents
loading

Table of Contents