Comtech EF Data CDM-Qx Installation And Operation Manual page 152

Multi-channel satellite modem with doubletalk carrier-in-carrier
Hide thumbs Also See for CDM-Qx:
Table of Contents

Advertisement

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier®
Ethernet Management
Events Log
(Available only on the Base nested Status page) – This scrollable read-only window provides a
visual record of stored events:
Read Next Five Events: Click to buffer the next group of five stored events into the
events window.
Clear Events Log: Click to wipe clean the stored events log.
Initialize Events Pointer: Click to Selecting this button to reset the log's internal
pointer.
Unread Events: Displays the total number of unread stored events in the Events
window. As stored event groups are displayed, this number adjusts downward
accordingly.
Once the desired settings have been entered, the user should then click [Submit] as needed to
execute update of this section.
Alarm Mask
A variant of this section permits the user to configure Alarm Masks for the base unit and
individual modules. Note the following:
(For the Base nested Status page) – Select the alarm mask for the Reference Osc(illator)
as Masked or Unmasked.
(For the Tx, Rx, or MD nested Status pages) – The selections available for Tx, Rx, or
MD Alarm Masks depend on the data interface selected for the particular module/group
(i.e., RS422; V.35; RS232; HSSI; ASI; G.703; or QDI). Set the pertinent alarm mask as
Masked or Unmasked.
For any configuration, once all desired alarm masks have been set, click [Submit Alarm Mask].
Internal Redundancy
(Available only on the Base nested Status page) – These read-only fields indicate the redundancy
configuration status for each module slot.
Alarms
A variant of this read-only section permits the user to view alarms for the Tx and Rx modules.
Note the following:
(For the Tx and MD nested Status pages) – Alarms associated with modulation are
displayed in this read-only window.
(For the Rx and MD nested Status pages) – Alarms associated with demodulation are
displayed in the provided read-only window. Additionally, Eb/No, BER, Freq Offset, Rx
Buffer Fill State, and Rx Signal Level (RSL) operating parameters are monitored.
(For only the MD nested Status page) – In addition to the Tx and Rx Alarms, Carrier-in-
Carrier (CnC) and AUPC operating parameters are monitored.
For any configuration, click [Read Status] to refresh the available read-only text boxes or windows
to their most current values.
6–22
Revision 7
MN/CDMQX.IOM

Advertisement

Table of Contents
loading

Table of Contents