4. Certain wireless access points offer proprietary settings or advanced functionality that differ from prevailing
industry standards. If you use these APs in the device group, you may wish to take advantage of this
proprietary functionality.
To configure these settings, locate the proprietary settings areas on the Groups > Radio page and continue
with the additional steps in this procedure.
Note: Proprietary settings are only applied to devices in the group from the specific vendor and are not configured on devices
from vendors that do not support the functionality.
5. To configure HP ProCurve 420 settings exclusively, locate the HP ProCurve 420 section and adjust these
settings as required.
Table 62 HP ProCurve 420 Fields and Default Values
Setting
Slot Time
Multicast Data Rate
Rogue Scanning
Rogue Scanning Interval (15-
10080 min)
Rogue Scanning Duration (50-
1000 msec)
Rogue Scan Type
6. To configure the HP ProCurve 240, Enterasys AP 3000 and AP 4102 Operational Mode and Max Station Data
Rate, locate the HP ProCurve 240, Enterasys AP 3000 and AP 4102 section of the Proprietary Settings area,
and define the settings.
Table 63 HP ProCurve 240, Enterasys AP 3000 and AP 4102 Fields and Default Values
Setting
Operational Mode
Max Station Data Rate
7. To configure settings specific to Enterasys AP3000 and Enterasys AP4102, locate the Enterasys AP3000 and
Enterasys AP4102 section of the Proprietary Settings area, and define the settings.
settings and default values of this page.
102
| Configuring and Using Device Groups in AWMS
Table 62
describes the settings and default values.
Default
Description
Auto
Short-slot-time mechanism, if used on a pure 802.11g deployment, improves
WLAN throughput by reducing wait time for transmitter to assure clear channel
assessment.
5.5Mbps
Sets the maximum data rate of the multicast data packets.
Enabled
If enabled the 420 APs in the group will scan for rogues.
720
If rogue scanning is enabled, this setting controls the frequency with which
scans are conducted (in minutes). Frequent scans provide the greatest security,
but AP performance and throughput available to user devices may be impacted
modestly during a rogue scan.
NOTE: This setting only applies to Periodic scans.
350
Specifies the amount of time, in milliseconds, the AP should spend performing
the rogue scan. If the duration is set too high users may start to experience
connectivity issues.
NOTE: This setting only applies to periodic scans.
Periodic
Specifies the Rogue Scanning mode. When set to Dedicated, users are unable to
associate to the AP.
Table 63
describes the settings and default values of this page.
Default
Description
802.11b +
Sets the radio operational mode for all of the ProCurve 420s, Enterasys 3000s and
802.11g
4102sin the group to either b only, g only,
or b + g.
54 Mbps
The maximum data rate at which a user can connect to the AP.