Manufactured Mobile Home Additional Requirements; Locating Your Gas Fireplace; Heatwave Duct Kit; Heat Release Kit - Regency LIBERTY L676E-LP Owners & Installation Manual

Gas fireplace
Table of Contents

Advertisement

INSTALLATION
10) Install standard and optional features. Refer
to the following sections:
a)
Interior Brick Panels
b)
Log Set
c)
Exterior Brick Panels
d)
Remote Control - refer to "Matching
Remote Handset & Control Box
ID Code" section.
11) Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly and operation fully explained to
customer.
This includes:
1) Clocking the appliance to ensure the correct
fi ring rate (rate noted on label 42,000 (NG)
Btu/h, 40,000 (LP) Btu/h) after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut
or weakened during installation.
2) Ensure proper grounding using the #8
ground lug provided. See "Wiring Diagram"
section.
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your fi replace,
ensure that the clearances are met.
2) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
The appliance must be installed on a metal
or wood panel extending the full width and
depth of the appliance.
3) The L676E Direct Vent Gas Fireplace can
be installed in a recessed position or framed
out into the room as in A, B, C and D. See
Diagram 1.
8
A)
Flat on Wall
B)
Flat on Wall Corner
C)
Recessed into
Wall/Alcove
D)
Corner
Diagram 1
4) This appliance is Listed for bedroom
installations using the standard FireWizard
Remote. Some areas may have further
requirements, check local codes before
installation.
5) The L676E Direct Vent Gas Fireplace
is approved for alcove installations, see
"Clearances" section for details.
6) We recommend that you plan your installation
on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation.
Note: For vent terminations refer to
"Exterior Vent Termination Locations"
section.
HEATWAVE
DUCT KIT
The HeatWave Air Duct Kit increases the
effectiveness of your fi replace by dispersing
warm air from the fi replace to remote locations in
the same room or other rooms in your home.
Up to two kits may be installed on the fi replace.
Please Note: Only 1 HeatWave kit may be
operated at one time.
See HeatWave installation manual for complete
details and clearances from side only.
The HeatWave Duct Kit has different
clearance and framing requirements,
check the HeatWave manual for details.

HEAT RELEASE KIT

The Heat Release Kit expels warm air from the
fi replace to the outside of the building, allowing
the fi replace to be operated with less heat entering
the room. The kit may be used on either the left
or right side.
See Heat Release installation manual for complete
details and clearances from side only.
HEARTH
REQUIREMENTS
A minimum 29-1/8" (737mm) wide x 12" (305mm)
deep x 2" (51mm) thick non-combustible hearth
is required if the fi nished fl oor is not fl ush with the
base of the unit. The maximum height between
the fi nished fl oor and sub-fl oor is 1" (25mm).
NOTE: No hearth is required when the unit is fl ush
with the fi nished fl oor as shown below.
The minimum fl oor clearance must be maintained
from the top surface of the carpet, etc. to the
unit base.
Regency
®
L676E Direct Vent Gas Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liberty l676e-ng

Table of Contents