Clearances; Locating Your Fireplace; Manufactured Mobile Home Additional Requirements - Regency PG36NG3-R Manual

Table of Contents

Advertisement

INSTALLATION
LOCATING YOUR
FIREPLACE
1) When selecting a location for your fi replace,
ensure that the clearances outlined on this
page are met.
2) P r o v i d e a d e q u a t e c l e a r a n c e s f o r
servicing.
3) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
fl ooring, the appliance must be installed on
a metal or wood panel extending the full
width and depth of the appliance.
4) The PG36 Co Axial Flue Gas Fireplace
can be installed in a recessed position or
framed out into the room as in A, B, C, D.
See Diagram 1.
A)
Flat on Wall
B)
Flat on Wall Corner
C)
Recessed into Wall/Alcove
D)
Corner
5) This appliance is Listed for bedroom
installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The PG36 Co Axial Flue Gas Fireplace is
approved for alcove installations, which meet
the clearances listed on this page.
7) We recommend that you plan your installation
on paper using exact measurements for
clearances and fl oor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation.
Note: For flue terminations see the
"Exterior Flue Termination Locations"
section.
6
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut
or weakened during installation.
2) Ensure proper grounding using the #8
ground lug provided. Refer to the "Wiring"
section.

CLEARANCES

The clearances listed below are Minimum
distances unless otherwise stated:
A major cause of chimney related fi res is
failure to maintain required clearances (air
space) to combustible materials. It is of the
greatest importance that this fi replace and
fl ue system be installed only in accordance
with these instructions.
Clearance to Combustibles from:
Back
Side
Floor
Diagram 1
Clearances for Bay or Flush Front
Min. 8"
(203mm)
Min. 6"
(152mm)
Clearances for Barcelona Front
NOTE: The minimum fl oor clearance must
be maintained from the top surface of the
carpeting, tile, etc.
Minimum Clearance from Top of Unit to:
Mantel* Minimum
Ceiling from top of unit.
Side Wall Clearance
Bay or Flush Front
Barcelona Front
Horizontal Flue Clearances
Top
Side
Bottom
Vertical Flue Clearances
Alcove Clearances**:
Max. Depth
Min. Width
Min. Height
* see mantle clearance instructions
(Refer to the "Combustible Mantels," & "Mantel
Leg Clearances" sections.)
**Approved for one sidewall installation
0"
(0mm)
only when using Barcelona Front.
0"
(0mm)
0"
(0mm)
Fire hazard is an extreme
risk if these clearances
are not adhered to.
For more Barcelona Framing and Installation
Notes, see the "Framing and Finishing"
section.
BARCELONA FRAMING NOTE: If the
Barcelona Trim is to be installed, the front
face of the fi replace must be made of non-
combustible material. See Diagram 1.
Regency
7"
(177mm)
32" (1016mm)
6"
(152mm)
8"
(203mm)
2"
(51mm)
1-1/2" (38mm)
1-1/2" (38mm)
1-1/4" (32mm)
36"
(914mm)
48"
1219mm)
72"
1829mm)
WARNING
Diagram 1
®
PG36-3 Gas Log Fireplace