WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
919-442e
Liberty
MODELS:
Owners & Installation Manual
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
L234 Gas Insert
®
L234-NG10 Natural Gas
L234-LP10 Propane
09.29.20

Advertisement

Table of Contents
loading

Summary of Contents for Regency Liberty L234 Series

  • Page 1 Liberty L234 Gas Insert ® MODELS: L234-NG10 Natural Gas L234-LP10 Propane Owners & Installation Manual Liberty L234 Product Video WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace.
  • Page 3: Table Of Contents

    table of contents Installation Wiring Diagrams ............26 Optional Wall Thermostat ...........27 MA Code - CO Detector ..........5 Final Check ..............27 (for the State of Massachusetts only) ......5 DC Spark Igniter ............27 For Your Safety ..............7 Battery Installation ............27 Important Message ............8 First Fire ..............28 Gas Pressure Testing ............8 Specifications ..............8...
  • Page 4 Ensure that the safety label is attached to the unit. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 5: Ma Code - Co Detector

    requirements MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 6 dimensions Shown with Low Profile Faceplate ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Liberty L234-10 Direct Vent Gas Insert ®...
  • Page 7: For Your Safety

    installation FOR YOUR SAFETY YOUNG CHILDREN SHOULD BE CARE- FULLY SUPERVISED WHEN THEY ARE This appliance requires air for proper combustion. IN THE SAME AREA AS THE APPLI- Always provide adequate combustion and ANCE. TODDLERS, YOUNG CHILDREN ventilation air. Follow instructions and information in CSA B149.1 (in Canada) or the National Fuel Gas AND OTHERS MAY BE SUSCEPTIBLE Code ANS Z223.1/NFPA (in the USA), regarding...
  • Page 8: Important Message

    INSTRUCTIONS with local codes or in the absence of local codes, with CAN/CSA B149.1 (in Canada) The Regency Direct Vent Gas Insert must be or the National Fuel Gas Code ANSI Z223.1 installed in accordance with these instructions. NFPA 54 in the U.S.A. This appliance should...
  • Page 9: Gas Pressure Testing

    installation GAS PRESSURE FACTORY-BUILT (METAL) WOOD- TESTING BURNING FIREPLACE REQUIREMENTS The appliance must be isolated from the gas sup- ply piping system by closing its individual manual NOTE: Any parts that are removed must be removed shut off valve during any pressure testing of the in a way that would allow them to be re-installed if gas supply piping system at test pressures equal the insert is ever removed (removal of rivets or...
  • Page 10: Installation Checklist

    Aeration System" section. damper plate from falling down and crushing the liner. Ensuring that the appliance is venting correctly. The Regency Gas Insert is installed as listed below. 1) Check all clearances to combustibles. Refer MATERIALS to the following sections where applicable: REQUIRED a.
  • Page 11: Minimum Clearances To Combustibles

    installation COMBUSTIBLE MANTEL CLEARANCES MINIMUM CLEARANCES TO COMBUSTIBLES Unless otherwise stated the clearances listed below are Minimum distances Because of the extreme heat this fireplace emits, the mantel clear- to combustible materials. Please Note: A major cause of chimney related ances are critical.
  • Page 12: Venting

    948-305 3" Flex - 35 ft. (exhaust) INSTALLATION WITH 3" & 3" LINERS 948-316 2" Flex - 35 ft. (intake) 946-582 Regency Co-linear DV Ver tical Ter mination Cap, Flashing & 2" Collar Part # Description 948-305 3" Flex - 35 ft. (intake & exhaust) 946-529 Regency Co-linear DV Vertical Termination Cap &...
  • Page 13: Converting From 3" & 3" Venting To 3" & 2

    installation CONVERTING FROM 3" & 3" VENTING TO 3" & 2" VENT RESTRICTOR POSITION 1) Remove the top plate from the unit by undoing the screw at the front The Vent Restrictor plate is located on the inside top of the firebox. of the firebox and slide out towards the back of the unit.
  • Page 14: Flue Liner Installation

    installation FLUE LINER GAS CONNECTION INSTALLATION 1) Cut the flex liner as required. GAS CONNECTION WARNING: Only persons licensed to work with gas piping may 2) Mark the end of one liner with an "E" to indicate exhaust. make the necessary gas connections to this appliance. 3) Connect the other end of the above liner to the exhaust side of the 1) When the appliance is to be installed into either an existing masonry termination cap, seal connection with high temperature silicone.
  • Page 15: Gas Insert Aeration Adjustment

    Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty. Note: Aeration Adjustment should only be performed by an authorized Regency Installer at the time of installation or service. 4. Remove the logs. 1. Remove the outer faceplate.
  • Page 16: Gas Pipe Pressure Testing

    installation GAS PIPE SIT 829 VALVE DESCRIPTION PRESSURE TESTING 1) Gas on/off knob 2) Electronically Operated Hi/Lo The appliance must be isolated from the gas supply piping system by 3) Pilot Adjustment closing its individual manual shut-off valve during any pressure testing of 4) Thermocouple Connection - option the gas supply piping system at test pressures equal to or less than 1/2 5) Outlet Pressure Tap...
  • Page 17: Conversion From Ng To Lp

    L234-10 / L234-11 installation CONVERSION KIT #537-969 FROM NG TO LP CONVERSION FROM NG TO LP LP Conversion Instructions THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!! LP Conversion Kit Contains: 7.
  • Page 18: Optional Brick Panel Installation

    L234 installation BRICK PANEL INSTALLATION OPTIONAL BRICK PANEL INSTALLATION NOTE: Brick Panels are mandatory when using Optional Remote 1) Carefully remove the brick panels from the box and unwrap them. 3) Slide the right side brick panel into position and secure in place using the brick clip.
  • Page 19: Safety Screen Install

    installation SAFETY SCREEN INSTALL GLASS DOOR REMOVAL/INSTALL 1. Slide the folded tab on the screen assembly over the tab on the glass door (left and right sides). 1. Remove the glass door. Tab on screen assembly a) Pull the spring hook on the left that holds the door in place. Place the hook into the opening towards the outside of the bracket.
  • Page 20: Log Set Installation

    L234 installation LOG SET INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the images. Dangerous operating conditions may occur if the logs are not positioned in their correct locations. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
  • Page 21 L234 installation 6) Place log 2-715 into the pin on log 2-712 and rest the right end of the log on the notch in log 2-713. 2-715 2-712 2-713 2-712 5) Fit the left side of log 2-713 into the pin on log 2-714 and rest the right side of the log on the burner plate pushing it against the tab.
  • Page 22 L234 installation 7) Place embers on the right side of the burner as shown. Fit log 2-716 into the pin on log 2-712. 2-716 2-712 Right side of Burner Also place a few embers along the burner tube next to log 2-713. Separate platinum embers and place on and around the embers.
  • Page 23 installation L234 Completed Log Set Installation 2-711 2-715 2-712 2-713 2-714 2-716 Liberty L234-10 Direct Vent Gas Insert ® 918-674a 01/03/08...
  • Page 24: Low Profile Faceplate Installation

    L234 installation LOW PROFILE FACEPLATE INSTALLATION LOW PROFILE FACEPLATE INSTALLATION 4. Install safety screen over glass door by opening glass door and slid- 1. * If no spacer required–proceed to Step 2. ing tab of safety screen over tab of glass door as shown below, then If optional spacer is required, secure the faceplate backing to the install door and screen together.
  • Page 25: Hearth Trim Installation

    installation HEARTH TRIM INSTALLATION OPTIONAL HEARTH TRIM Customize Hearth Trim: 2) Attach the supplied brackets to the top of the hearth trim with 2 screws. Note: orientation of brackets is different when using spacer. a) The Hearth Trim can be adjusted to custom fit an installation by pulling apart the top piece from the bottom piece.
  • Page 26: Wiring Diagrams

    installation WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. However, WARNING: Electrical Grounding Instructions a 120V A.C. power supply is needed for the fan/blower operation. This appliance is equipped with a three pronged (grounding) plug for your protection against Caution: Ensure that the wires do not touch any hot shock hazard and should be plugged directly into surfaces and are away from sharp edges.
  • Page 27: Optional Wall Thermostat

    (noted on label) at 15 minutes. NOTE: The battery in the DC Sparker Box will length. Regency offers an optional programmable need to be replaced annually. thermostat but any 250-750 millivolt rated non-...
  • Page 28: First Fire

    operating instructions FIRST FIRE which will be located on the bottom of the appli- ance. This remote control requires coding. See 5. Press and release the ON/OFF button on the remote control instructions for details. remote handheld transmitter. An audible beep The first fire in your insert is part of the paint curing should be heard from the receiver.
  • Page 29: Copy Of Lighting Instruction Plate

    être Blower: mortelles. Regency gas appliances use high tech blowers Une mauvaise installation, un mauvais réglage, une altération ou un entretien mal effectué peut en- traîner des dégâts matériels ou des blessures. Reportez-vous au manuel d'utilisation fourni avec to push heated air farther into the room.
  • Page 30: Maintenance

    GENERAL VENT purchase your replacement from an authorized GUARD REMOVED FOR SERVICING MAINTENANCE Regency dealer only, do not use substitute materials. AN APPLIANCE MUST BE REPLACED Follow our step-by-step instructions for replacement. P R I O R O P E R AT I N G...
  • Page 31: Fan Replacement

    maintenance FAN REPLACEMENT b) Swing the door out 45 degrees and lift up 8) Remove the burner tray by undoing the 4 1) Unplug the power source. and out. screws. 2) Remove the faceplate. 3) Remove the safety screen. 4) Remove the glass door. a) Pull the spring hook on the left that holds the door in place.
  • Page 32 maintenance 10) Remove the fan cover plate by undoing the 12) Remove the 2 screws that hold the fan bracket 15) Replace the fan. 12 screws that hold it in place. in place. NOTE: Bend the connector clips down before re-installing the fan cover plate.
  • Page 33: Valve Replacement

    maintenance VALVE REPLACEMENT 6) Disconnect the gas connection to the valve. 1) Remove the faceplate - see instructions in b) Swing the door out 45 degrees and lift up manual. and out. 7) Disconnect the ignitor wire from the DC Sparker.
  • Page 34 maintenance 10) Remove the burner by undoing the 3 screws. 12) Remove the rear log tray by undoing the 3 screws. Valve Removed 14) Replace the valve. 15) Reverse steps 13 - 1. Rear Log Tray Removed Burner Removed 11) Remove the burner tray by undoing the 4 13) Remove the 12 screws that hold the valve screws.
  • Page 35: Gas Maintenance

    Gas Maintenance GAS MAINTENANCE - RECOMMENDED ANNUAL ROUTINE Recommended Annual Routine Maintenance for Gas Fireplaces, Stoves and Inserts In order for your Regency appliance to continue to provide comfort to your home periodic maintenance must be performed to ensure it is operating at peak efficiency. The items in the list should be checked by a licensed gas service technician during the annual service check. Your unit may require more frequent maintenance checks if you notice any changes in how it operates. Operational changes to look for can include, but are not limited to, extended start up time, increased fan noise, residue/carbon build up, white build up on the glass/firebox, increased operating noise etc. Should any of these or other conditions arise, discontinue use and schedule a service check with your local licensed gas technician. The list below shows items your licensed service technician will need to check and service at least annually. Clean Inspect Check • Glass • Pilot assembly • Voltage on thermocouple/thermopile (mil- • Interior bricks / panels • Burner livolt models) •...
  • Page 36: Main Assembly

    parts list MAIN ASSEMBLY Part # Description 936-170 Orifice Gasket 940-355/P Glass Part # Description 536-539 Door Frame Assembly no Glass 537-574/P Valve Assembly - NG 536-540 Door Frame Assembly with Glass 537-576/P Valve Assembly - LP 948-463 Burner Assy - NG/LP 536-092 Log Tray Middle 910-073...
  • Page 37 warranty MAIN ASSEMBLY Liberty L234-10 Direct Vent Gas Insert ®...
  • Page 38 parts list 537-924 Low Profile Faceplate 38 | Liberty L234-10 Direct Vent Gas Insert ®...
  • Page 39 notes Liberty L234-10 Direct Vent Gas Insert ®...
  • Page 40: Warranty

    FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. Revision Date: February 2019 Regency Gas Products Warranty 40 | Liberty L234-10 Direct Vent Gas Insert ®...
  • Page 41 Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: February 2019 Regency Gas Products Warranty Liberty L234-10 Direct Vent Gas Insert ®...
  • Page 42 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
  • Page 43 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 44 warranty 44 | Liberty L234-10 Direct Vent Gas Insert ®...
  • Page 45 notes Liberty L234-10 Direct Vent Gas Insert ®...
  • Page 46 notes 46 | Liberty L234-10 Direct Vent Gas Insert ®...
  • Page 48 Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial #: ____________________________________________________________ Liberty L234 Product Video Printed in Canada Regency and Liberty are trademarks of Regency Fireplace Products International Ltd. © Copyright 2020, Regency Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Liberty l234-ng10Liberty l234-lp10

Table of Contents