9) Carefully remove the bottom brick panel.
Bottom Brick Panel
10) Loosen the 2 screws that hold the right side heat shield in place.
11) Lift the heat shield up and pull out slightly to clear the head screws
and then hang it on the top bracket (located directly above the heat
shield, close to the top of the fi rebox).
12) Disconnect both sources of power; the power cord, located on the
left hand side of the fi rebox and the wires connected to the back-up
battery located on the right side of the fi rebox.
40
13) Disconnect the inlet gas line from the valve.
14) Disconnect the 2 connectors from the modulating coil and the wire
harness.
Heat
Shield
15) Remove the control box by carefully lifting off the velcro and sliding it
out from the side of the fi rebox.
NOTE: The control box will need to be fl ipped as it is being brought
out from the side of the fi rebox.
Back-up
Battery
shown
Wire Harness Disconnected
Regency
®
L676E Direct Vent Gas Fireplace
Wire Harness
Connectors