Venting Arrangements; Allowable Vertical Terminations - Regency LIBERTY L676E-LP Owners & Installation Manual

Gas fireplace
Table of Contents

Advertisement

INSTALLATION
The shaded area in the diagram shows all allowable
combinations of straight vertical and offset to vertical
terminations, using two 90
o
elbows, with Rigid Pipe
Venting Systems for Propane and Natural Gas.
Two 45
o
elbows equal to one 90
o
of four 45
elbows allowed.
Vent must be supported at offsets.
Firestops are required at each fl oor level and
whenever passing through a wall.
Maintain clearances to combustibles as listed
in the "Clearances" section.
Refer to "Vent Restrictor Position" section for
details on how to change the vent restrictor
to Set 1, Set 2 or Set 3 if required.
Note: Must use optional fl ue adapter when using
Rigid Pipe (Part # 770-994).
22

VENTING ARRANGEMENTS

ALLOWABLE VERTICAL TERMINATIONS

o
elbow. Maximum
Regency
®
L676E Direct Vent Gas Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liberty l676e-ng

Table of Contents