Table of Contents

Advertisement

LRI4E / HRI4E Gas Insert
MODELS: LRI4E-NG Natural Gas
HRI4E-NG Natural Gas
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
919-380_a
LRI4E-LP Propane
HRI4E-LP Propane
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Owners &
Installation Manual
Liberty LRI4E
Horizon HRI4E
www.regency-fire.com
05.04.15

Advertisement

Table of Contents
loading

Summary of Contents for Regency LRI4E

  • Page 1 Owners & LRI4E / HRI4E Gas Insert Installation Manual Liberty LRI4E Horizon HRI4E www.regency-fire.com MODELS: LRI4E-NG Natural Gas LRI4E-LP Propane HRI4E-NG Natural Gas HRI4E-LP Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2 The Regency Gas Insert Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The models LRI4E / HRI4E of this series have been approved by Warnock Hersey/Intertek for both safety and efficiency.
  • Page 3: Table Of Contents

    (LRI4E / HRI4E)............18 Glass Burner install .............43 Conversion from NG to LP ........19 LRI4E ceramic burner Removal / installation .....44 Glass crystal / ceramic spa stone installation ....21 Fan maintenance - with GTMF remote control ....45 Optional PebbleS / GLASS crystal Installation for Valve replacement ............46...
  • Page 4: Unit Dimensions With Vignette Faceplate

    UNIT DIMENSIONS WITH VIGNETTE FACEPLATE (762mm) 21-11/16" (550mm) 41-5/8" (1056mm) 14-7/16" (366mm) 35-1/8" (891mm) 18” 24.181 (457mm) 614.20 LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 5: Unit Dimensions With Low Profile Faceplate

    UNIT DIMENSIONS WITH LOW PROFILE FACEPLATE LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 6 UNIT DIMENSIONS WITH 4 SIDED VIGNETTE FACEPLATE LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 7 This is a copy of the labels that accompany each LRI4E Gas Insert. We NOTE: Regency units are constantly being improved. Check the label on have printed a copy of the contents here for your review. the unit and if there is a difference, the label on the unit is the correct one.
  • Page 8: Safety Decal

    This is a copy of the labels that accompany each HRI4E Gas Insert. We NOTE: Regency units are constantly being improved. Check the label on have printed a copy of the contents here for your review. the unit and if there is a difference, the label on the unit is the correct one.
  • Page 9: Ma Code - Co Detector

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 10: Important Message

    IN THE SAME AREA AS THE APPLI- ANCE. TODDLERS, YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE The LRI4E / HRI4E Gas Inserts must be installed in TO ACCIDENTAL CONTACT BURNS. A accordance with these instructions. Carefully read all the instructions in this manual first. Consult the PHYSICAL BARRIERS IS RECOMMEND- "authority having jurisdiction"...
  • Page 11: Important Message

    FOR YOUR SAFETY air passageways of the appliance be kept clean. The LRI4E / HRI4E Gas Inserts have been tested and approved to be vented into any masonry 4) See general construction and assembly fireplace or approved solid fuel burning factory This appliance requires air for proper combustion.
  • Page 12: Installation Checklist

    1) Check all clearances to combustibles, (Refer to MINIMUM FIREPLACE DIMENSIONS sections "Minimum Fireplace Dimensions and Clearances to Combustibles) The minimum fireplace clearances & dimensions for the Regency gas insert are shown in the following diagrams: 2) Make the gas connection. (Refer to section "Gas Connection") 3) Install the two 3"...
  • Page 13: Minimum Clearances To Combustibles

    Note: All material used must be completely non-combustible. LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 14: Gas Connection

    However, keep the flexible liner as straight as possible, avoid Gas & Electrical Connections unnecessary bending. The Air Intake pipe must be attached to the inlet 14 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 15: Flue / Vent Installation

    Flue Connector Plate Gasket WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 16: Levelling Leg Adjustment

    LEVELLING LEG ADJUSTMENT The LRI4E / HRI4E inserts are equipped with 2 rear levelling legs that are accessible while the appliance is in its final installation position. The unit can be adjusted up to 5/16" (16mm). Remove left and right side filler pieces. The rear levelling bolts are located in the back corners of the firebox and can be adjusted using a 7/16" wrench.
  • Page 17: Air Shutter Adjustment

    The LRI4E / HRI4E is equipped with an air shutter that is accessible from outside the firebox and can be adjusted during operation.
  • Page 18: System Data

    6) When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Note: Screw should be snug, but do not over tighten. 18 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 19: Proflame Remote System Gtmf With Fan (Lri4E / Hri4E)

    PROFLAME REMOTE SYSTEM GTMF WITH FAN (LRI4E / HRI4E) Proflame System Configuration 886 GTMF Wire Diagram Proflame Remote Operation Proflame Remote Battery Change GTMF REMOTE SYSTEM - IMPORTANT: The 120V fan control module serves as the power source for this unit. The AA batteries in the receiver only serve as a backup in case 120 volt power lost within the home.
  • Page 20: Conversion From Ng To Lp

    M4 x .7 screws supplied. Tighten the screws to 25lb-in. In the event that the screw threads are cross threaded or stripped, replace the valve The valve in the LRI4E is attached using 2 screws and 2 hooks located assembly.
  • Page 21 9) Remove pilot retainer clip with pliers and pull off the pilot cap to expose the pilot orifi ce. 13) Adjust aerations settings - see Air Shutter Adjustment section in the manual. Installer Notice: These instructions must be left with the appliance Pilot retainer clip LRI4E / HRI4E Direct Vent Gas Insert 919-409 07/07/14...
  • Page 22: Glass Crystal / Ceramic Spa Stone Installation

    Glass Crystals Pebbles HRI4E 5 lbs burner 1 package (use 3 bags pebbles) Installing Glass Crystals Glass Crystals shown on Burner and Firebox Floor DO NOT block pilot area with glass crystals 22 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 23 HZI390E ADDENDUM installation CAUTION DO NOT place spa stones over pilot and burner ports. No spa stones in this area. LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 24: Hri4E Optional Log Set Installation

    Reapply glass crystals to pilot cover Pilot Area screen. See picture on Step 3 9-1/4" Position Log 2 Rear Log Brackets 24 | LRI4E / HRI4E Direct Vent Gas Insert 919-350a 11.17.14...
  • Page 25 12. Adjust aeration setting to fully open (manual for detailed instruc- HRI4E Pin Landing tions) Note: Logs to be installed in NG units only. Line up pin locator and pin, Logs 5,4 LRI4E / HRI4E Direct Vent Gas Insert 919-350a 11.17.14...
  • Page 26: Lri4E Log Set Installation

    Log 3 push to the back of the indent Log 2 pin locator, line up with pins on burner 26 | 919-408 07.03.14 LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 27 Log 7 and Log 2 should make contact Location for Log 5 7. Log 6 is positioned in the indent on the far right of the burner in the orientation shown below. Final Install Location for Log 6 LRI4E / HRI4E Direct Vent Gas Insert 919-408 07.03.14...
  • Page 28: Standing Pilot

    STANDING PILOT The LRI4E / HRI4E use a heat exchanger and efficient combustion technol- ADDING THE HEAT EXCHANGER RETURN ogy to provide extreme heating efficiencies. The more efficient an appliance becomes, the lower the flue gas temperatures becomes. On start-up, flue temperatures are required to initiate venting action.
  • Page 29: Brick Panel Installation

    Liner Rear. The side Liner will hold the rear Liner in place. Install the Fire- box Liner Left the same way you installed the Firebox Liner Right. Both side liners should be just slightly back from the front edge of the Firebox. Brick Panel Installation LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 30: Enamel Panel Installation

    You may have to push the liner against the firebox as you push it rearward. Panel retainers Installing Enamel Panels HRI6E *Insulation panels not shown in this diagram 30 | LRI4E / HRI4E Direct Vent Gas Insert 07/30/14 919-025c...
  • Page 31: Glass Door Removal / Installation

    6) Pull the bottom of the door towards you until the door is angled away from the firebox by about 30°. Lift the door up and over the upper door hooks. 7) To install the glass door - reverse steps. Glass Door Cleaning & Removal LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 32: Vignette Faceplate With Safety Screen Installation

    Use a grommet and wire clip to secure. Final Install Note:Shown with Optional Hearth Trim NOTE: Pull the bottom of the Vignette faceplate towards you to access the remote receiver Power Cord Location 32 | LRI4E / HRI4E Direct Vent Gas Insert 09.19.14 919-417...
  • Page 33: Sided Low Profile Faceplate With Safety Screen Installation

    LRI4E / HRI4E / LRI6E / HRI6E installation 3 SIDED LOW PROFILE FACEPLATE WITH SAFETY SCREEN INSTALLATION 3 SIDED LOW PROFILE FACEPLATE W/SAFETY SCREEN INSTALLATION Note: A mantel deflector may be installed to reduce the minimum mantel height. 4. Install front faceplate by hooking back of front faceplate over lip edge on Refer to minimum clearances in the installation manual.
  • Page 34: Sided Faceplate With Safety Screen Installation

    4 SIDED FACEPLATE WITH SAFETY SCREEN INSTALLATION 1. Install the outer faceplate and secure with 6 screws as shown. 2. Install the outer faceplate by hooking the flange over the hanger as shown. 34 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 35: Spacer Installation

    Route power cord through the inner and outer rear profi le of the rear faceplate on the right side. Install grommet and wire clip. 3. Install the Vignette faceplate by hooking the fl ange over the hanger. See Vignette Installation Instructions LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 36: Backing Plate Installation

    2. Install the outer faceplate and secure with 6 screws as shown. Route power cord through the inner and outer profile of faceplate Power cord 3. Install the outer faceplate and secure with 6 screws as shown. 12.04.14 919-419 36 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 37: Optional Mantel Deflector Installation

    The tabs should be flush with the underside of the top lip of the back plate. Top of backing plate Note: Faceplate may be installed after the unit is in its final position. Installed mantel deflector 3RD ANGLE TOLERANCES UNLESS LRI4E / HRI4E Direct Vent Gas Insert 919-421 09.22.14...
  • Page 38 3) Similar to the front hearth trim, cut the top of the bottom piece of the spacer brackets to the appropriate height. 4) Attach the top and bottom part of the spacer brackets and then attach these spacer brackets to the assembled hearth trim with 3 screws. 38 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 39 3) Reattach the top piece of the hearth trim to the cut bottom piece by tting in place. 4) Line up the hearth trim with base of the unit and secure it with 3 screws as shown below. LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 40: Operating Instructions

    The fan will turn on as the stove comes up to operating temperature. After the unit has been turned off and the unit cooled to below a useful heat output range the fan will shut off automatically. 40 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 41: Lighting Procedure

    2. Press and release the ON/OFF button on the remote handheld transmit- to the unit. ter (see Diagram 2). An audible beep should be heard from the receiver. ON/OFF Button Diagram 2 Remote shown in Manual Mode on Hi LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 42: Normal Operating Sounds Of Gas Appliances

    Utilisez l'interrupteur murale ON/OFF du Brûleur ou du contrôle à distance pour éteindre le brûleur. Si le service est effectuée–vous devez débrancher l'alimentation et coupez le gaz à l'unité. DO NOT REMOVE THIS INSTRUCTION PLATE 919-401a 42 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 43: Maintenance Instructions

    1 around the thermocouple, and 1 flowing across the rear of the burner (it does not have to be touching the burner). Glass Door Cleaning & Removal Window Glass Door Components LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 44: Pilot Adjustment

    GLASS GASKET If the glass gasket requires replacement use glass gasket for the Flush Front (Part # 936-112). 44 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 45: Glass Crystal Burner Removal / Installation - Hri4E

    ** Do not to install glass or other media over or in front of the Pilot Provision as shown. Important: Do not to install glass or other media in this area, as this will black the path of the pilot to the burner. LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 46: Lri4E Ceramic Burner Removal / Installation

    Ceramic Burner and the firebox Bottom Flange. The Burner should be situated about ¼” (6mm) inside the front edge of the firebox. 4) To install - reverse Steps 3-2, see Step 1 for correct installation tips. 46 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 47: Fan Maintenance - With Gtmf Remote Control

    1/4" spade connectors to the fan terminals. Disconnect the ground lug to the fan using the screw provided. Strain Relief Power Cord Fan Controller Wire Retainer Fan Wire Harness Fan Terminals Ground Wire Fan Mounting Bracket Diagram 2 LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 48: Valve Replacement

    3) Disconnect the Pressure Regulator cable. 7) Remove both Screws that secure the Gas Valve Mounting brackets, both sides. Pressure regulator cable 4) Disconnect the Gas Orifice supply line from the outlet of the Gas Valve. 48 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 49 15) Reconnect the gas and electrical supply to the unit. Once the unit has be re-fired, use a soapy water mixture to check all fittings and gas sup- ply lines for gas leaks. LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 50: Parts List

    911-012 Ignition board SIT IPI 911-137 Pilot Hood Holding Clip 910-572 SIT Proflame receiver Part Not Shown 911-074 Pilot Assy Ground Wire 396-043 Firebox Liner Retainers 396-114 Burner End - L 50 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 51 LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 52: Vignette Faceplate

    Oversize faceplate - Metallic Black (2 piece) 399-912 Accent trim - Platinum (2 piece) 399-926 4 sided faceplate (custom sizes) - Metallic Black 399-913 Accent trim - Chrome (2 piece) 399-916 Accent trim-Tuscan Sunset (2 piece) 52 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 53 LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 54 54 | LRI4E / HRI4E Direct Vent Gas Insert...
  • Page 55: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufac- turer defect. The authorized selling dealer is responsible for all in-field service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 56 Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Liberty LRI4E Horizon HRI4E Regency and Regency Horizon, are trademarks of FPI Fireplace Products International Ltd. ® Printed in Canada © Copyright 2015, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Hri4eHri4e-ngLri4e-lpLri4e-ngHri4e-lp

Table of Contents