Regency LIBERTY L676E-LP Owners & Installation Manual page 21

Gas fireplace
Table of Contents

Advertisement

One 90
o
elbow = Two 45
Option V
H
V + V1
A)
2' Min.
2' Max. 3' Min.
B)
2' Min. 10' Max. 6' Min.
C)
3' Min.
6' Max. 4' Min.
D)
4' Min.
7' Max. 5' Min.
E)
5' Min.
8' Max. 6' Min.
VENT RESTRICTOR SETTING:
Vent restrictor must be at Set 0 for both NG and LP.
One 90
o
elbow = Two 45
Option
V
H + H1 V + V1
A)
2' Min.
2' Max.
B)
3' Min.
4' Max.
C)
4' Min.
5' Max.
D)
5' Min.
6' Max.
E)
6' Min.
8' Max.
VENT RESTRICTOR SETTING:
Vent restrictor must be at Set 0 for both NG and LP.
Regency
®
L676E Direct Vent Gas Fireplace
Vertical Venting with Two (2) 90
o
elbows.
With these options, max. total pipe
length is 30 feet with min. of 6 feet
total vertical and max. 10 feet total
horizontal.
Please note min. 1 foot between
o
90
elbows is required.
Vertical Venting with Three (3) 90
o
elbows.
With these options, max. total
pipe length is 30 feet with min.
4' Min.
of 9 feet total vertical and max.
6' Min.
8 feet total horizontal.
7' Min.
Please note min. 1 foot
8' Min.
between 90
o
elbows is
9' Min.
required.
INSTALLATION
o
Elbows
o
Elbows
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liberty l676e-ng

Table of Contents