Clearances; Locating Your Gas Fi Replace; Manufactured Mobile Home Additional Requirements - Regency PG36D-NG Owners & Installation

Table of Contents

Advertisement

INSTALLATION
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your stove,
ensure that the clearances outlined on this
page are met.
2) P r o v i d e a d e q u a t e c l e a r a n c e s f o r
servicing.
3) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
fl ooring, the appliance must be installed on
a metal or wood panel extending the full
width and depth of the appliance.
4) The PG36D Co Axial Flue Gas Fireplace
can be installed in a recessed position or
framed out into the room as in A, B, C, D.
See
Diagram 1.
A)
Flat on Wall
B)
Flat on Wall Corner
C)
Recessed into Wall/Alcove
D)
Corner
5) This appliance is Listed for bedroom
installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The PG36D Co Axial Flue Gas Fireplace
is approved for alcove installations, which
meet the clearances listed on this page.
7) We recommend that you plan your installation
on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation.
Note: For fl ue terminations see section
" E x t e r i o r F l u e Te r m i n a t i o n
Locations."
6
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut
or weakened during installation.
2) Ensure proper grounding using the #8 ground
lug provided. See section "Wiring."

CLEARANCES

The clearances listed below are Minimum
distances unless otherwise stated:
A major cause of chimney related fi res is
failure to maintain required clearances (air
space) to combustible materials. It is of the
greatest importance that this fi replace and
fl ue system be installed only in accordance
with these instructions.
Clearance to Combustibles from:
Back
Side
Floor
Diagram 1
Clearances for Bay or Flush Front
Min. 8"
(203mm)
Min. 6"
(152mm)
Clearances for Barcelona Front
NOTE: The minimum fl oor clearance must
be maintained from the top surface of the
carpeting, tile, etc.
Minimum Clearance from Top of Unit to:
Mantel* Minimum
Ceiling from top of unit.
Side Wall Clearance
Bay or Flush Front
Barcelona Trim
Horizontal Flue Clearances
Top
Side
Bottom
Vertical Flue Clearances
Alcove Clearances**:
Max. Depth
Min. Width
Min. Height
* see mantle clearance instructions
(Refer to section "Combustible Mantels" &
"Mantel Leg Clearances."
**Approved for one sidewall installation
only when using Barcelona Front
0"
(0mm)
0"
(0mm)
0"
(0mm)
if these clearances
are not adhered to.
For more Barcelona Framing and Installation
Notes, see section "Framing and Finishing."
BARCELONA FRAMING NOTE: If the
Barcelona Front is to be installed, the front
face of the fi replace must be made of non-
combustible material. See Diagram 1.
Fr ont Fr am i ng D i m ensi ons usi ng
M i n.6"
( 153m m )
Regency
7"
(177mm)
32" (1016mm)
6"
(152mm)
8"
(203mm)
2"
(51mm)
1-1/2" (38mm)
1-1/2" (38mm)
1-1/4" (32mm)
36"
(914mm)
48"
1219mm)
72"
1829mm)
WARNING
Fire hazard is an
extreme risk
t he B ar cel ona O pt i on
N on- com bust i bl e
M at er i al
Steel
Steel
Stud
Stud
36- 1/ 4"
( 921m m )
M i n.6"
( 153m m )
Diagram 1
®
PG36D Gas Log Fireplace