Download Print this page

Regency Sunrise Gas Fireplace L676S-LP1 Specification Sheet

Regency gas fireplaces specification sheet
Hide thumbs Also See for Sunrise Gas Fireplace L676S-LP1:

Advertisement

Regency L676-1 Sunrise Gas Fireplace
Model
Fuel Type
Minimum Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifi ce Size
Minimum Input
Altitude 0-4500 ft. (0-1372m)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
Vent Sizing
Approved Venting Systems
Flex Vent Systems:
Rigid Pipe Vent Systems:

Unit Dimensions:

Unit Dimensions
Description
A
Firebox Width w/ Standoff
B
Rear Firebox Width
C
Firebox Height
D
Height w/ Standoff
E
Unit Depth
F
Height to Vent
G
Fireplace Opening Height
H
Fireplace Opening Width
I
Height to Fireplace Opening
This manual is intended to be a Sales Reference Guide only.
Do NOT use for actual framing and installation of any unit.
Some specifi cations may change without notice.
You must use the actual manual for exact installation specifi cations.
WARNING
Failure to maintain required clearances is a major cause of chimney related fi res.
Installation of this fi replace must comply with these clearances
Please note: Due to ongoing product development, product appearance and specifi cations
are subject to change without notice.
L676S-NG1
L676S-LP1
Natural Gas
Propane
5" W.C. (1.25 kPa)
12" W.C. (2.98 kPa)
3.5" W.C. (0.87 kPa)
10" W.C . (2.49 kPa)
1.6" W.C. (0.40 kPa)
6.4" W.C (1.59kPa)
#37 DMS
#53 DMS
19,500 BTU/h
21,000 BTU/h
(5.71 kW)
(6.15kW)
29,000 BTU/h
26,000 BTU/h
(8.49 kW)
(7.61kW)
5" Inner / 8" Outer
5" Inner / 8" Outer
FPI AstroCap™ Flex Vent
Simpson Direct Vent Pro®
Selkirk Direct-Temp™
Metal-Fab® Sure Seal
L676S-1
42-1/2" (1080mm)
33-1/8" (841mm)
37-3/8" (949mm)
45-5/8" (1159mm)
24" (610mm)
40-3/8" (1026mm)
29-1/16" (738mm)
31-5/8" (803mm)
3" (76mm)

Framing Dimensions:

Framing Dimensions
Description
J
Framing Width
***
***
K
Framing Height
L
Framing Depth
M
Minimum Height to Combustibles
N
Corner Wall Length
O
Corner Facing Wall Width
P
Vent Centerline Height
Q
Non-combustible Facing Height
R
Gas Connection Opening Height
S
Gas Connection Height
T
Gas Connection Inset
U
Gas Connection Opening Width
***
Important: Framing height requires consideration of the hearth
depth. Dimension K = K + the thickness of installed hearth.
Non-Combustible Requirements:
44-1/2"
(1130mm)
Non-combustible
Material
31-5/8"
(803mm)
Non-combustible Material
6-7/16"
(163mm)
L676-1 Sunrise Gas Fireplace
L676S-1
43" (1092mm)
***
45-7/8" (1165mm)
+ Hearth
24-1/2" (622mm)
56-1/4" (1429mm)
57-3/16" (1453mm)
80-13/16" (2052mm)
49-1/4" (1251mm)
15-9/16 (395mm)
2" (51mm)
11-1/4" (286mm)
5-3/4" (146mm)
5" (127mm)
Metal
Stud
Finished Floor
3"
(76mm)

Advertisement

loading

Summary of Contents for Regency Sunrise Gas Fireplace L676S-LP1

  • Page 1: Framing Dimensions

    Regency L676-1 Sunrise Gas Fireplace Model L676S-NG1 Fuel Type Natural Gas Minimum Supply Pressure 5” W.C. (1.25 kPa) Manifold Pressure - High 3.5” W.C. (0.87 kPa) Manifold Pressure - Low 1.6” W.C. (0.40 kPa) Orifi ce Size #37 DMS Minimum Input 19,500 BTU/h Altitude 0-4500 ft.
  • Page 2: Finishing Requirements

    - to ensure the faceplate can be removed. 36 -1/4” Regency L676-1 Sunrise Gas Fireplace Important: A 3/4" gap must be maintained all around the outer edge of the faceplate and the edge of any fi nishing material thicker than 1-1/4").
  • Page 3: Vertical Terminations

    Regency L676-1 Sunrise Gas Fireplace Clearance Requirements: Installed Close to Floor Clearance: Dimension A: Mantel Height 16-1/2” (419mm) B: Sidewall 14-3/4” (375mm) C: Ceiling 52” (1321mm) D: Mantel Depth 13” (330mm) E: Alcove Width 84” (2134mm) F: Alcove Depth 36” (914mm) Combustible Mantels Because of the extreme heat this fi...

This manual is also suitable for:

Sunrise gas fireplace l676s-ngL676s-ng1 sunrise