Regency L850B Owners & Installation

Montrose wood fireplace

Advertisement

Quick Links

Owners &
Installation
MONTROSE WOOD FIREPLACE
Model: L850B
PLEASE KEEP THESE INSTRUCTIONS FOR
FUTURE REFERENCE
WARNING:
Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. Refer to this manual. For assistance
or additional information consult an authorised installer, service agency
or the distributor.
It is highly recommended for protection of infants and infirm to place a
secure safety guard in front of this appliance when in operation.
FPI - FIREPLACE PRODUCTS AUSTRALIA PTY LTD.
919-370
November-20-2014
1 CONQUEST WAY HALLAM VICTORIA 3803

Advertisement

Table of Contents
loading

Summary of Contents for Regency L850B

  • Page 1 Owners & Installation MONTROSE WOOD FIREPLACE Model: L850B PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult an authorised installer, service agency or the distributor.
  • Page 2 The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning.
  • Page 3: Table Of Contents

    table of contents APPLIANCE MAINTENANCE Data Badge................4 Unit Dimensions ..............5 Creosote ................25 Standard Features and Optional Accessories .......6 Ash Removal ...............25 Glass Installation ..............25 INSTALLATION Glass Maintenance ..............25 Before Installing Your Fireplace ..........7 Door Latch Adjustment ............25 Safety Guidelines and Warnings ...........8 Trouble Shooting ..............26 Wood Fireplace Specifications ..........9 Wood Fireplace Specifics-Minimum Clearances ....10...
  • Page 4: Data Badge

    This is a copy of the data badge that accompanies improved. Check the data badge on the unit each L850B Fireplace. We have included a copy of and if there is a difference, the data badge on the contents here for your review.
  • Page 5: Unit Dimensions

    dimensions DIMENSIONS UNIT DIMENSIONS Montrose Woodfire...
  • Page 6: Standard Features And Optional Accessories

    Slow Combustion Fireplace Above: Regency Montrose shown as a clean edge install. Designed for modern living, the Regency Montrose will add ambience and enjoyment to any room. The large viewing glass with black etched edge provides an exceptional view of the fire whilst complimenting the décor of any home.
  • Page 7: Installation

    Regency Fireplaces are constructed with the highest quality materials and assembled under strict quality control procedures that insure years of trouble free and reliable performance. It is important that you read this manual thoroughly and fully understand the safe installation and operating procedures. The more you understand the way your Regency Fireplace operates, the more enjoyment you will experience from knowing that your unit is operating at peak performance.
  • Page 8: Safety Guidelines And Warnings

    6) Do not permit creosote or soot build-up in the chimney system. DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT Check and clean chimney at regular intervals. Failure to do so can IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CON- result in a serious chimney fire. SIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE. 7) Your Regency stove can be very hot. You may be seriously burned if you touch the stove while it is operating, keep children, clothing and CAUTION: CRACKED AND BROKEN COMPONENTS, e.g. GLASS furniture away. Warn children of the burn hazard. For safety reasons PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION a guard around the fire is recommended. UNSAFE. 8) The stove consumes air while operating, provide adequate ventila-...
  • Page 9: Wood Fireplace Specifications

    installation UNIT DIMENSIONS Optional Ducting Flue Dimensions ● 2 x Optional fan forced ducting vents ● Minimum 4.5 Meters of triple skin are available, using 150mm ducting to flue required with approved cowling The outside dimensions of the Montrose L850 including the Zero a max run of 9 Meters Clearance Box is as follows: ●...
  • Page 10: Wood Fireplace Specifics-Minimum Clearances

    installation WOOD FIREPLACE SPECIFICS AND MINIMUM CLEARANCES Framing Guide Hearth Requirements Hearth needs to be 6mm thick and 1470mm wide and 995mm deep to allow for Unit cavity to be open into the roof cavity. 300mm leading edge. W e do recommend though that your non-combustible hearth extend 900mm in front of the unit. This allows the floor to be protected when the Cavity Must be open extending to attic. No ceiling within cavity. door is fully open in case of ember drop. Wall Cladding Floor Protection The floor protector must be a minimum of 300mm deep in front of the appliance Non-combustible material such as 9mm cement sheeting base. However it is highly recommended due to the width of the appliance door...
  • Page 11: Optional Base Frame

    installation OPTIONAL BASE FRAME - REVISION B (HEIGHT CHANGED TO 300MM) CONSTRUCTING YOUR OWN BASE FRAME WHEN BUILDING YOUR OWN BASE FRAME OR PEDESTAL BASE PLEASE ENSURE THE FOLLOWING CONDITIONS ARE MET. 1. MINIMUM HEIGHT OF THE BASE FRAME IS 300MM FROM THE FINISHED FLOOR TO THE UNDERSIDE OF THE ZERO SHELL. IF BASE FRAME DOES NOT SIT ON THE SAME LEVEL OF THE FINISHED FLOOR, THEN THE FRAME NEEDS TO BE MADE TALLER TO ENSURE THE 300MM CLEARANCE IS MET.
  • Page 12: Flue And Chimney Requirements

    installation FLUE AND CHIMNEY REQUIREMENTS PLEASE READ AND REFER TO INSTALLATION INSTRUCTIONS UNIT PREPARATION ON PAGE 16 Top of Unit prior to installation of the flue. The packaging material has been 3. 8" inner galvanized skin fitted. The flue sits down in the box. Note: Crimped removed end is up.
  • Page 13 installation 10" galvanized flue skin over ventilation plate. Note tab on either side-bent up to secure flue via self drilling screws 6. Before the next steps ensure all clearances/installation codes have been met. Test the fan for proper operation. 7. Note ventilation at top of outer flue where it meets the cowl. It must be vented to allow heat to escape.
  • Page 14 installation FLUE AND CHIMNEY REQUIREMENTS THE FLUE PIPE SHALL EXTEND NOT LESS THAN 4.6 M ABOVE THE TOP OF THE FLOOR PROTECTOR. NOTE: INSTALLATION MUST BE CARRIED OUT BY A LICENSED INSTALLER IN ACCORDANCE WITH AS/NZS 2918:2001 Montrose Woodfire...
  • Page 15 installation FLUE AND CHIMNEY REQUIREMENTS Typical Example of a Sloped Ceiling Penetration Example of Roof Penetration Montrose Woodfire...
  • Page 16: Installation Instructions

    installation INSTALLATION INSTRUCTIONS UNIT PREPARATION/FRAMING/CLEAN EDGE AND FACEPLATE WALL FINISHING BEFORE INSTALLING ENSURE THE FOLLOWING: 8. Remove the two screws on the back of the unit labelled "packing screws". READ THE ENTIRE MANUAL EVALUATE THE LOCATION OF YOUR FIREPLACE AND LOCA- TION OF OPTIONAL COMPONENTS SUCH AS FAN, OUTSIDE AIR AND FACEPLATE.
  • Page 17 installation INSTALLATION INSTRUCTIONS UNIT PREPARATION/FRAMING/CLEAN EDGE AND FACEPLATE WALL FINISHING 10. Remove the six nuts and bolts and bolts that are used to secure the Clean 12. When using the Faceplate Option, the firebox needs to be pulled forward Edge Frame to the unit. Discard the Clean Edge Frame and hardware. out of the Zero Shell to the predetermined thickness of the finish material.
  • Page 18 installation INSTALLATION INSTRUCTIONS UNIT PREPARATION/FRAMING/CLEAN EDGE AND FACEPLATE WALL FINISHING 15. Install the nailing strips. The unit comes with four nailing strips. The top, 16. When using the Faceplate option, the finishing materials sit behind the left and right side are all the same and the bottom one is the smaller piece. firebox flange when the unit is pulled forward to the pre-determined depth.
  • Page 19 installation INSTALLATION INSTRUCTIONS UNIT PREPARATION/FRAMING/CLEAN EDGE AND FACEPLATE WALL FINISHING 17. When using the Clean Edge Frame, position the nailing flanges to the pre-determined thickness of the finish material. The finish materials and non- combustible board are to sit flush with the edge of the Clean Edge Frame. Using the scrap pieces as a gauge position them so they are flush with the front edge of the clean edge frame.
  • Page 20: Optional Fan Kit Installation

    installation L850 Montrose OPTIONAL FAN KIT INSTALLATION OPTIONAL FAN KIT INSTALLATION LISTINGS AND CODE GENERAL Maximum Duct Run: 9.0m Kit Contains 4.5m APPROVALS INFORMATION If you require more than 4.5m please purchase Fan Duct Extension Kit. This Fan Kit has been approved for use with The Fan Kit increases the effectiveness of Montrose L850.
  • Page 21: Fan Kit Installation

    installation L850 Montrose OPTIONAL FAN KIT INSTALLATION OPTIONAL FAN KIT INSTALLATION 9) Secure the collar within to the three tabs using the NOTE: Installation of Fan Kit should be done prior Air Duct screws provided. to installation of the wall. L850 Montrose 2) Mount and secure the fan housing assembly to Fan Housing...
  • Page 22: Fan Duct Extension Kit

    L850 Montrose installation OPTIONAL FAN KIT INSTALLATION OPTIONAL FAN KIT INSTALLATION FAN DUCT EXTENSION KIT FAN DUCT EXTENSION KIT In order to use the fan extension duct kit, you must have fan kit. This kit allows you to extend the fan duct to 9m. 2.
  • Page 23: Optional Outside Air Kit Installation

    installation OPTIONAL OUTSIDE AIR KIT INSTALLATION L850 Montrose OUTSIDE AIR KIT INSTALLATION When installing the outside air kit please ensure your pedestal base the unit 3. Install the adapter ensuring it is centered on the primary air opening. sits on is hollow in the center. The outside adapter attaches to the bottom of Secure in place with the provided screws.
  • Page 24: Brick Installation

    installation BRICK INSTALLATION Firebricks are not in place at time of delivery to prevent damage. Place 3 rear bricks at back of fireplace firstly. Then place 2 side bricks in position left and right. 3 x Baffle Bricks need to be placed in position at top of fire. Finally insert 2 firebricks on the base of the firebox. Firebricks are included as an integral part of the unit and not only enhance operating performance hence compli- ance of the unit but also to extend the life of your firebox. These must be replaced if damaged in any way in order not to Void the Warranty Montrose Woodfire...
  • Page 25: Appliance Maintenance

    Safety Precautions slow burning fire. As a result, creosote residue ment from an authorized Regency dealer only, and 1) Do not allow ashes to build up to the loading accumulates on the flue lining. When ignited, this follow our step-by-step instructions for replacement.
  • Page 26: Trouble Shooting

    installation TROUBLE SHOOTING Symptom Possible Cause Solution Symptom Possible Cause Solution The combustion air control Ensure that the air control is open The door may have been Ensure that the door is properly is closed, or insufficient and that the air inlet is free from left open, or the door latch closed and that when latched that combustion air is reaching...
  • Page 27: Operating Instructions

    operating instructions OPERATING AIR SLIDE CONTROL FUEL REQUIREMENTS INSTRUCTIONS Both the primary and air wash drafts are controlled BURN ONLY HARDWOOD TIMBER THAT HAS by the control rod located at the bottom of the unit BEEN SEASONED AND THE MOISTURE CON- With your unit now correctly installed and safety (when facing the unit).
  • Page 28: Lighting The Appliance

    CAUTION: Never leave unit unattended if door is left open. This procedure your home, a downdraft may be created by your Regency Stove causing a is for fire start-up only, as unit may overheat if door is left open for too long. draft down your chimney. If this occurs, slightly open a window near your unit. CAUTION: If the body of your unit, flue baffle or any part of the chimney 4) With the draft still in the fully open position add two or three seasoned logs connector starts to glow, you are over firing.
  • Page 29: Parts List

    MAIN ASSEMBLY 1) 1565000 Firebox Shell 12) 1560402A L850B Fascia 2) 1561000 Firebox Assembly 1560402B (Not Shown) L850B Fascia with box 4) 1560500 Back Secondary Air Tube 13) 1562200 Door Handle 5) 1563000 Front Secondary Air Tube 14) 1567000 Air Damper Assembly...
  • Page 30: Installation Of Appliance Checklist

    WARRANTY warranty INSTALLATION OF APPLIANCE CHECKLIST For future reference and to assist in any warranty claim please complete the following information. In the unlikely event of a problem, contact your installer or dealer for assistance: APPLIANCE WAS PURCHASED FROM Name: Address: Telephone Number: MODEL DETAILS...
  • Page 31 Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency Fireplace Product's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested. In areas where there is not an approved service agent or the closest approved service agent is situated more than thirty (30) kilometres from the installation, Regency is not obliged to arrange warranty repairs and travel and/or additional labour charges will apply.
  • Page 32 Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.