Regency Sunrise Gas Fireplace L676S-NG1 Owners & Installation Manual

L676 sunrise gas fireplace
Hide thumbs Also See for Sunrise Gas Fireplace L676S-NG1:
Table of Contents

Advertisement

L676 Sunrise
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-758c
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Fireplace
MODELS: L676S-NG1 Natural Gas L676S-LP1 Propane
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
www.regency-fi re.com
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
02/06/09

Advertisement

Table of Contents
loading

Summary of Contents for Regency Sunrise Gas Fireplace L676S-NG1

  • Page 1 Homeowner: Please keep these instructions for future reference. Owners & Installation Manual www.regency-fi re.com FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch: do not use any phone in your building.
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The L676S has been designed to provide you with all the warmth and charm of a fi replace at the fl ick of a switch.
  • Page 3: Table Of Contents

    Unit Installation with Horizontal Termination ...25 Unit Installation with Vertical Termination ...26 Unit Installation ...27 Horizontal Termination w/Flex Vent System ...27 High Elevation ...28 Regency® L676S Direct Vent Gas Fireplace TABLE OF CONTENTS Gas Line Installation ...28 Pilot Adjustment ...28 Gas Pipe Pressure Testing ...28 SIT 820 Valve Description ...28...
  • Page 4: Safety Label

    * Alcove side wall must have a min. of 14-3/4” (375mm) clearance on one side. ** Mantel depth taken at 26-1/2” (673mm) from front facing. FPI Fireplace Products International Ltd., Delta BC, CANADA MADE IN CANADA / FABRIQUE AU CANADA Regency® L676S Direct Vent Gas Fireplace CSA 2.33a-2007, (1.25 kpa) (0.39 kpa) (0.87 kpa)
  • Page 5: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency® L676S Direct Vent Gas Fireplace...
  • Page 6: Unit Dimensions

    UNIT DIMENSIONS Regency® L676S-1 Direct Vent Gas Fireplace...
  • Page 7: Installation

    ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE- CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. Regency® L676S Direct Vent Gas Fireplace YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
  • Page 8: Manufactured Mobile Home Requirements

    The maximum height that combustible fl oor can be brought above the base of the unit is 0". Note: If fi nished fl oor is any higher than the base of the unit, the facepate will not fi t into place. Regency® L676S Direct Vent Gas Fireplace...
  • Page 9: Clearances

    (air space) to combustible materials are not adhered to. It is of greatest importance that this fi replace and vent system be installed only in accordance with these instructions. Regency® L676S Direct Vent Gas Fireplace CLEARANCES “NON-COMBUSTIBLE FACING” 3”...
  • Page 10: Mantel Clearances

    Allowable mantel leg projection Side wall Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. L676S UNIT 9” (229mm) 11” (279mm) 14-3/4” (375mm) Regency® L676S Direct Vent Gas Fireplace...
  • Page 11: Framing & Finishing

    Note: The 24-1/2" fl ush framing depth (and the corner framing installation) are based upon 1/2" drywall around the perimeter of the fi replace on all three sides. Diagram 2 Regency® L676S Direct Vent Gas Fireplace INSTALLATION FRAMING Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed.
  • Page 12 This gap is required to facilitate the installation of the faceplate and to ensure the removal of the faceplate for service access. 36 -1/4” Diagram 3 3/4" Finishing Material (thickness + 1-1/4") Diagram 4 Regency® L676S Direct Vent Gas Fireplace...
  • Page 13 Diagram 5 Regency® L676S Direct Vent Gas Fireplace INSTALLATION To accommodate various thicknesses of facing material - the faceplate is adjustable to a maximum of 1-1/4" and a minimum of 1/2" . See chart below and page 35 for detailed instructions.
  • Page 14: Unit Assembly Prior To Installation

    Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited. Regency® L676S Direct Vent Gas Fireplace...
  • Page 15: Vent Restrictor Position

    Release the 2 door latches on the left and right side at the top of the fi rebox. Latch Location Regency® L676S Direct Vent Gas Fireplace VENT RESTRICTOR POSITION Latch b. Swing the door out from the top and release the hinge on the left side of the door and lift out.
  • Page 16: Exterior Vent Termination Requirements

    3 feet (91cm) above - if within 10 feet (3m) horizontally Canada 12"(30cm) 12"(30cm) 12"(30cm) 9" (23cm) 24"(60cm)) 24"(60cm)) 24"(60cm) 24"(60cm) 13"(33cm) 13"(33cm) 13"(33cm) 13"(33cm) 13"(33cm) 13"(33cm) 13"(33cm) 13"(33cm) 36"(90cm) 36"(90cm) 12"(30cm) 9" (23cm) 72"(1.8m) 36"(90cm) 84"(2.1m) ‡ 12"(30cm) Regency® L676S Direct Vent Gas Fireplace...
  • Page 17: Venting Arrangements

    S.S. screws #8 x 1-1/2” drill point 10) vinyl siding standoff Horizontal Terminations) 5” dia. flue pipe 8” dia. Flue pipe Regency® L676S Direct Vent Gas Fireplace VENTING ARRANGEMENTS HORIZONTAL TERMINATION (FLEX) Regency ® Direct Vent System Vinyl Siding...
  • Page 18: Rigid Pipe Venting Systems

    (Part #946-623/P) Wall Thimble (Mandatory in all Horizontal Terminations) When using Rigid Vent other than Simpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor. ® Direct Vent Pro and Selkirk Direct-Temp. Regency® L676S Direct Vent Gas Fireplace...
  • Page 19: 5" X 8" Rigid Pipe Cross Reference Chart

    INSTALLATION 5” X 8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Regency® L676S Direct Vent Gas Fireplace...
  • Page 20 INSTALLATION Regency® L676S Direct Vent Gas Fireplace...
  • Page 21: Venting Arrangements

    Firestops are required at each fl oor level and whenever passing through a wall. • A wall thimble is mandatory for all horizontal terminations due to high temperatures. Regency® L676S Direct Vent Gas Fireplace VENTING ARRANGEMENTS Horizontal (Feet) on Set 3...
  • Page 22 With these options, max. total pipe length is 30 feet with min. of 11 feet total vertical and max. 9 feet total horizontal. Please note min. 1 foot between 90 elbows is required. Elbows Elbows Regency® L676S Direct Vent Gas Fireplace...
  • Page 23 6' Min. 8' Max. 9' Min. VENT RESTRICTOR SETTING: Vent restrictor factory set at Set 1, no adjustment required. Regency® L676S Direct Vent Gas Fireplace Elbows elbows. With these options, max. total pipe length is 30 feet with min. of 9 feet total vertical and max.
  • Page 24: Allowable Vertical Terminations

    Set 1 to Set 2 or Set 3 if required. Note: Must use optional fl ue adapter when using Rigid Pipe (Part # 770-994). VENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONS elbows equal to one 90 elbows, with elbow. Maximum of four 45 elbows allowed. Regency® L676S Direct Vent Gas Fireplace...
  • Page 25: Unit Installation With Horizontal Termination

    Silicone (red RTV) is optional. Diagram 1 Regency® L676S Direct Vent Gas Fireplace Horizontal runs of vent must be supported every 3 feet (0.9meter). Wall straps are available for this purpose.
  • Page 26: Unit Installation With Vertical Termination

    8) Install the vertical termination cap by twist- locking it. Note: Any closets or storage spaces, which the vent passes through must be enclosed. Off set Chart Regency® L676S Direct Vent Gas Fireplace...
  • Page 27: Unit Installation

    (0.9 meter). (Flame picture and performance will be aff ected by sags in the liner). Regency® L676S Direct Vent Gas Fireplace 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom.
  • Page 28: High Elevation

    1) Gas on/off knob 2) Manual High/Low Adjustment 3) Pilot Adjustment 4) Thermocouple Connection - option 5) Outlet Pressure Tap 6) Inlet Pressure Tap 7) Pilot Outlet 8) Main Gas Outlet 9) Alternative TC Connection Point Regency® L676S Direct Vent Gas Fireplace...
  • Page 29: Aeration Adjustment

    Assembly DC Spark Ground Burner ON Black Regency® L676S Direct Vent Gas Fireplace AERATION ADJUSTMENT 1) Remove burner, see page 30 for detailed instructions. 2) Adjust aeration setting on ventury cap with a phillips head screwdriver. WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing controls.
  • Page 30: Conversion From Ng To Lp

    LP orifi ce #53. Burner Orifi ce 7) Remove the NG pilot orifice with the 5/32 Allen Key and replace with LP pilot orifi ce. 8) Reinstall the pilot cap. Pilot Cap Regency® L676S Direct Vent Gas Fireplace...
  • Page 31 11) Check that the screw is clean and if necessary remove dirt. 12) Flip the screw (Fig. 3). Fig.3 Regency® L676S Direct Vent Gas Fireplace 13) Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.
  • Page 32: Panel Installation

    Failure to do this will result in burn stain on panels which you will be unable to remove. Not protected by product warranty. Back panel. Slots on fl oor of fi rebox base. Regency® L676S Direct Vent Gas Fireplace...
  • Page 33 Note: Only use hole closest to back panel to secure panel clip, the panel clips can be used on either the left or right side. Use this hole on panel clip. 5) Repeat steps 2-4 to install right side. Regency® L676S Direct Vent Gas Fireplace...
  • Page 34: Glass Crystal Or Optional Ceramic Stones Installation On Burner

    NOTE: When using Ceramic Stones, DO NOT cover burner ports that lead to pilot fl ame. Burner shown with optional Ceramic Stones Regency® L676S Direct Vent Gas Fireplace...
  • Page 35: Faceplate & Door Frame Installation

    3) If the Faceplate & Door Frame is not sitting level (fl at), remove and adjust the 2 Phillips screws located at the bottom of the faceplate. Level adjustment Regency® L676S Direct Vent Gas Fireplace INSTALLATION 5) The L676S Faceplate consists of 2 parts, an inner faceplate and an outer faceplate, these 2 faceplates will be shipped installed together as one piece.
  • Page 36: Operating Instructions

    fi lm will bake on and become very diffi cult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. Regency® L676S Direct Vent Gas Fireplace...
  • Page 37: Normal Operating Sounds Of Gas Appliances

    Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process. Regency® L676S Direct Vent Gas Fireplace OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any;...
  • Page 38: Maintenance

    WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualifi ed service person. Regency® L676S Direct Vent Gas Fireplace...
  • Page 39: Dc Spark Box Battery Replacement

    4) Re-install battery cover on DC Spark Box. 5) Reinstall the faceplate (see page 35). Regency® L676S Direct Vent Gas Fireplace DC SPARK BOX REPLACEMENT 1) Disconnect the 2 DC Spark generator wires from the DC spark box located on the right side of the fi...
  • Page 40: Valve Tray Replacement

    8) When side panels have been removed, tilt back panel towards front of fi rebox. 9) Lift back panel up and out from slots to remove. Slots for back panel 10) Remove bolts to lift out the fi rebox base. Regency® L676S Direct Vent Gas Fireplace...
  • Page 41 13) Disconnect the 2 DC Spark generator wires from the DC spark box located in front of the valve. Disconnect 2 generator wires Regency® L676S Direct Vent Gas Fireplace 14) Disconnect the spark electrode wire from the DC spark box. DC Spark Box Electrode Wire 15) Remove the 16 screws that hold the valve tray to the fi...
  • Page 42: Parts List

    GTM Remote Control 910-576 Cover Wall Mount 940- 910-572 Receiver GTM SIT w/Batt & Cover 946-556 Heat Wave Kit 946-570 Heat Release Kit 522-969 LP Converison Kit 918-758 Manual * Not available as a replacement part. Regency® L676S Direct Vent Gas Fireplace...
  • Page 43 PARTS LIST MAIN ASSEMBLY Heat Wave Kit Heat Release Kit Regency® L676S Direct Vent Gas Fireplace...
  • Page 44: Burner Assembly

    Firebox Base 22) 526-525 Burner Assembly NG/LP 23) 502-061 Shield Pilot 24) 910-586 Pilot Assembly 25) 904-240 NG Orifi ce #37 904-345 LP Orifi ce # 53 26) 910-568 Valve NG/LP 820 SIT BURNER ASSEMBLY Regency® L676S Direct Vent Gas Fireplace...
  • Page 45 NOTES Regency® L676S Direct Vent Gas Fireplace...
  • Page 46 NOTES Regency® L676S Direct Vent Gas Fireplace...
  • Page 47: Warranty

    ® ® thoroughly before it leaves our facility. Regency Fireplace Products is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This warranty is not transferable. The Warranty: Limited Lifetime The combustion chamber, heat exchanger, burner tubes/pans, logs, glass crystals, ceramic stones, pebbles, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime Warranty for fi...
  • Page 48 Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency Sunrise are trademarks of FPI Fireplace Products International Ltd. © Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved. In addition, our internal Quality ® online at Printed in Canada Regency®...

This manual is also suitable for:

Sunrise l676s-lp1

Table of Contents