Download Print this page

Nautilus NTR300 Owner's Manual page 34

Advertisement

Treadmill will not start
1. Not plugged in.
2. Safety pull pin not inserted.
3. Treadmill drcu[t breaker tripped.
Elevation not accurate
Speed not accurate
1. Out of calibration.
Walking belt slips
Walking belt not centered
Heart rate not displayed
(using chest strap)
1. Out of calibration.
2. Set in wrong units (kilometers or
miles)
1. Walking belt loose.
Walldng belt tension not
centered across the rear roller.
1. Transmitter not making good
contact with skin.
2. Electromagnetic interference.
1. Plug into three prong grounded
outlet.
2.
Insert safety pull pin.
3.
Reset circuit breaker
1. Recalibrate unit (See
Calibration Instructions).
1. Recalibrate unit (See Calibration
Instructions)
2. Change units (See Calibration
Instructions)
1. Adjust walking belt tension
(See "Taking Care of Your
Treadmill")
1. Adjust walking belt tension
(See "Taldng Care of '(our
Treadmill")
1. Moisten skin contact area on the
chest strap, or turn chest strap
upside down.
2. Turn off any television,
microwave, or computer within
6 feet (2 meters) of treadmill
Treadmill squeaks
1. Pivot points need lubrication.
1. Lubricate pivot points.
(SeeExplodedView)
LOCATING
THE
CIRCUIT
BREAKER
ON YOUR
TREADMILL
The
Breaker
is near
the
front
of the
treadmill
and
near
the
power
cord.
possible
circuit
breaker
locations
_---
frame
power cord
power cord
Tripped

Advertisement