Summit External Power Supplies

The following external power supplies are available for use with Summit X150 series, X250e series, X450
series, X450a series, and X450e series switches:
EPS-LD external power supply
EPS-160 external power module (used with EPS-T chassis)
EPS-500 external power supply
EPS-600LS external power module (used with EPS-C chassis)
EPS-150DC external power supply (used with EPS-T2 chassis)
Table 75: EPS-LD External Power Supply (Model 45019)
For use with the Summit X450a-24t and X450e-24p switches
Operational voltage range
Nominal input ratings
Input Current
Line frequency range
Maximum inrush current
Output
Power supply cord type
Power supply input socket
Power cord input plug
Power cord wall plug
Power supply cord gauge
Efficiency
Heat dissipation, Watts, BTU/hr
Power consumption, Watts, BTU/hr
Ambient operating temperature
Maximum continuous DC output shall not exceed 465 Watts.
376
(Table
75)
(Table
78)
90 to 264 V
100 to 240 V
, 50 to 60 Hz, 10 A
6 A at 100 V
, 2.5 A at 240 V
47 to 63 Hz
30 A at 115 V
, 60 A at 230 V
-50 V
, 7.5 A max, 375 Watts
12 V
, 7.5 A max, 90 Watts
AC
IEC 320 C14
IEC 320 C13
Refer to
"Selecting Power Supply Cords" on page
2
18 AWG (0.75 mm
or
2
16 AWG (1.0 mm
) over 6 feet
>75% at 100% load
123 W, 419.7 BTU/hr
588 W, 2006.3 BTU/hr
0° C to 40° C (32° F to 104° F)
Summit Family Switches Hardware Installation Guide
(Table
76)
(Table
79)
(Table
80)
) up to 6 feet or 2 meters