Chapter 10: Replacing DC Power Supplies in Summit Family Switches

Installing the Replacement Power Supply

To install a replacement Summit 850 W DC power supply:
1 Verify that the power supply is right side up (see
2 Carefully slide the power supply all the way into the power supply bay (see
power supply in until the latch snaps into place.
CAUTION
Do not slam the power supply into the switch.
Figure 286: Installing a Summit 850 W DC Power Supply

Connecting the Ground Wire

To connect the ground wire to the Summit 850 W DC power supply:
1 Verify that the DC circuit is de-energized.
2 Identify the grounding point on the front panel of the power supply (see
3 Insert an M3.5 screw (provided) through the ring terminal and into the grounding point on
the power supply.
4 Tighten the screw to 12.6 inch-pounds.
5 Connect the other end of the wire to a known reliable earth ground point at your site.
Figure 287: Connecting the Ground Wire
1 = Grounding point
2 = Ground wire