Serial Menu - Epson EPL-N2000 Reference Manual

Epson reference guide page printer epl-n2000
Hide thumbs Also See for EPL-N2000:
Table of Contents

Advertisement

Buffer Size
Determines the amout of memory to be used for receiving data
and printing data. If set to Maximum, more memory is
allocated for receiving data. If set to Minimum, more memory
is allocated for printing data. The factory default setting is
Normal.

Serial Menu

Word Length
You can select an 8-bit or 7-bit word length. See your computer
manual and software documentation for the proper setting.
The factory setting is 8-bit.
Baud Rate
Use this option to set the data transfer rate (baud) for the serial
interface. The baud rate is measured in bits per second (bps).
See your computer manual and software documentation for the
proper setting.
Parity
When this option is set to None, parity checking is disabled.
The parity bit, if used, provides a basic form of error detection.
See your computer manual and software documentation for the
proper setting.
Stop Bit
Use this option to set the number of stop bits for each character
of information sent to the printer. Stop bits signal the end of a
character.
5-17