Operation of the Fixing Assembly Temperature Control Sys-
tem
Power switch ON
WARM-UP
WARM-UP
ROTATION
Main motor (M1)
Scanner cooling fan (FM1)
Exhaust fan (FM2)
Fixing roller heater (H1)
Copy Start key indicator
Blinks green
183 C
170 C
160 C
145 C
50 C
0 C
*1: while the enagy saving mode, controlled at 100 C
Note:
• If the fixing temperature is shifted by service mode C17, the warm-up temperature is
shifted according to the fixing temperature.
• For pre-heating, the temperature control is not changed. However, LEDs on the control
panel are cut-off.
COPYRIGHT © 1999 CANON INC.
145 C 160 C
Copy Start key ON
SCANNER
STAND-BY
FORWARD
Glows green
*1
Figure 6-102
CANON NP6320 REV.0 DEC. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 6 FIXING SYSTEM
SCANNER
SCANNER
SCANNER
REVERSE
FORWARD
REVERSE
ROTATION
Glows red
Glows green
LAST