Module Problems
The screen below appears while the test is running. At the same time, if the
module has a green LED, it flashes.
Console Display/Instructions
Demand Test Slot xx:
aaaaaaaaaaaaaaaaaa
Board
Internal Loopback Test
in Progress
Exit
The screen below appears only if you selected
passes the test.
Demand Test Slot xx:
aaaaaaaaaaaaaaaaaa
Board
Internal Loopback Test
Successfully Completed
Exit
The screen below smears when either test
Demand Test Slot xx:
aaaaaaaaaaaaaaaaaa
Board
Internal Loopback Test
FAILED
xxxxxxxxxxxxxxxxxxxxxxxxx
xx xx xx xx xx xx xx xx
Exit
Lines 5 and 6 identify the cause of the failure or the number of errors found
per DSE port. There are 16 DSE ports, numbered 0 through 15. Line 5
displays the results for ports 0 through 7; Line 6 is for ports 8 through 15.
Interpreting Test Results
If the test is successful, the module DSE ports are free from error. Continue
with the next module test or restore the module if you are through testing.
4-48 Control Unit Problems
Additional Information
xx = slot number entered in Step 2
If you are running the repetitive test,
the screen remains until the test fails.
To interrupt repetitive testing, select
Exit.
Test Once
xx = slot number entered in Step 2
(Test Once
.
xx=slot number entered in Step 2
The 100D and 408 GS/LS-MLX
module each have two DSEs. To
display the second DSE's test
results, press the More button.
P C
and the module
or
fails.
Repetitive)
(PgUp)