Call Accounting Terminal
Considerations
You can connect only one CAT to the system. You must use a serial printer
such as the CAT printer. You must locate the CAT Plus within the distances
noted below:
Control unit
— 14 ft. (4.27 m) direct connection
— 1000 ft. (305 m) using building wiring
Serial printer, 50 ft. (15.2 m)
Power supply-grounded wall outlet, 4 ft. (1.22 m)
Hardware Requirements
The following hardware is required for CAT installation:
Call Accounting Terminal, CAT Plus
Serial printer (AT&T CAT Printer is recommended) connected by a
Z200A EMI cable to the PRINTER jack of the CAT
D8W cord and 355AF adapter connecting the SMDR port on the
communications system to the SMDR jack of the CAT
A summary of the installation procedure is provided below:
1 Before connecting the CAT, set the 10 CAT switches to establish the
speed or baud rate for the CAT and its associated printer.
2 Connect the control unit, CAT, printer, and power supply. See Chapter 5,
"Connecting a Printer to the Control Unit." Do not use an outlet that is
controlled by a wall switch.
3 Test the CAT Plus, following the instructions provided in the
documentation packaged with the application.