AT&T MERLIN LEGEND Release 3.0 Installation Manual page 213

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 3.0:
Table of Contents

Advertisement

Testing the System
Testing Ground-Start and Loop-Start Trunks
(Hybrid/PBX Systems Only)
To test the GS and LS outgoing and incoming trunks at a telephone, follow the
steps below:
1
Dial
followed by the trunk ID number (01 through 80).
*03
You should hear dial tone for a working trunk, a reorder tone for a DID trunk or
an invalid trunk number, or a busy tone if the trunk is in use.
NOTE:
Dialing
a single-line telephone works only if telephone has a touch-
*03
tone dialpad and the trunk accepts touch-tone dialing.
2
Repeat Step 1 for all outgoing trunks.
Dial an incoming trunk on the system.
3
4
Have someone answer the call at another telephone; verify that you have
good two-way communication.
5
Repeat Steps 3 and 4 for all incoming trunks.
Hang up to exit test mode.
6
Testing DID Trunks
To test DID trunks, follow the steps below:
1
Have someone at the central office check all DID trunks, or have
someone call from the outside to check each DID trunk.
2
When the first trunk rings, answer it.
Instruct the caller to put the call on hold or put down the handset while
3
making the next call.
4
When the next trunk rings, put the previous call on hold and repeat this
procedure until all eight DID trunks have been connected successfully.
5
When all trunks are connected with good communication, disconnect
each call and have the caller do the same.
7-8 Initializing and Testing the System