AT&T MERLIN LEGEND Release 3.0 Installation Manual page 216

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 3.0:
Table of Contents

Advertisement

Testing the System
Testing Two-Way Dial-Repeating Tie Trunks
For two-way dial-repeating tie trunks, perform both the incoming and outgoing
dial-repeating tie trunk tests.
Testing Incoming Dial-Repeating Tie Trunks
Perform this test for dial-repeating tie trunks that are two-way or incoming
only. If you are testing two-way dial-repeating tie trunks, perform the outgoing
test as well.
To test incoming dial-repeating tie trunks, follow the steps below:
1
Have the person at the far end place a dial-repeating call to your
telephone by dialing the proper tie-trunk number.
Your telephone rings, and the green LED next to lCOM (or SA for Hybrid/PBX
systems) flashes.
2
Pick up the handset.
The red LED next to the ringing button turns on, and the green LED changes
from flashing to steady.
Verify that you have good two-way communication and hang up.
3
The green LED should turn off, the red LED should turn off, and another red
LED may turn on.
4
Repeat Steps 1 through 3 for each incoming or two-way dial-repeating tie
trunk.
Testing Outgoing Dial-Repeating Tie Trunks
Perform this test for dial-repeating tie trunks that are two-way or outgoing only.
If you are testing dial-repeating two-way tie trunks, perform the incoming test
as well.
To test outgoing dial-repeating tie trunks, follow the steps below:
1 At any telephone that has access to a dial-repeating tie trunk, press the
first tie-trunk button.
The red LED next to the pressed tie-trunk button lights.
Initializing and Testing the System 7-11

Advertisement