Trunks
Planning Form Instructions
On the "Network Planning Map" (page 7 of Form 3c):
Fill in the control unit slot number(s) of the CSU(s) connected to the 100D
1 .
module(s).
Write the approximate number of cable feet between each module and its
2 .
CSU or far-end connection. (Refer to "Line Compensation" on page 1.)
Check the model number(s) of the CSU(s).
3 .
If "Other," write the manufacturer's name and model number in the
space provided at the bottom of the page.
If no CSU is needed, check "None."
In the connection block(s), describe the DS1's far-end connection.
4 .
Check "CO" if connected to the telephone company central office.
Check "PBX" if connected to another communications system.
Check "ISDN-PRI" if connected to the ISDN-PRI network.
Check the type(s) of emulated trunks if the facility's type of service is
T1. Also check Services" if the facility includes services such as
MultiQuest with DNIS.
Describe the clock synchronization sources according to the key at the
5 .
lower left of the map.
Draw a circle and line from the clock source to the appropriate 100D
m o d u l e .
Label the circle "P" for primary, "S" for secondary, and "T" for tertiary.
Make a copy of the "General Business Systems T1/ISDN-PRI Planner"
6 .
(Pages 5-7 of Form 3c) for your records and forward the original to AT&T
National Technical Marketing (NTM).
NTM also evaluates the complexity of the facility configuration requested.
Examples of complex configurations are connections into PBX networking
applications, connections to multiplexing arrangements, or applications that
involve customer engineering or design.
If an order is considered complex, NTM directs you to the Business
Communications System (BCS) National Engineering Center (NEC).
If NTM notifies you that the order's configuration is not complex, Tier Ill
General Business System (GBS) National Technical Service Center (NTSC) is
authorized to approve the configuration.
The NTSC group's pre-authorization review is based, in part, on information you
provide to them. Specifically, you must send them
a
copy of the planner (pages 5 through 7 of Form 3c)
a
completed 'Non-Complex Configuration' sheet (pages 9 through 11 of
Form 3c) for each 100D module you plan to install
Trunk Options 3-33