For Front Rack Access; Attaching The Outer Slide Rails To The Hp 9000 Series Rack - HP StorageWorks 2/32 - SAN Switch Installation Manual

San switch 2/32 version 4.0.x installation guide
Hide thumbs Also See for StorageWorks 2/32 - SAN Switch:
Table of Contents

Advertisement

3. Tighten the screws and torque to 15 inch-pounds.
4. Repeat steps 1 through 3 to install the left mount bracket on the left side of the

For Front Rack Access

Use these steps to attach the front rack mount brackets to the switch. The front
rack mount brackets act as "stops" to prevent the switch from sliding out the front
of the rack. Use these steps if you installed the inner slide rails to the switch using
the procedure outlined in
1. Align the right rack mount bracket with the two screw holes at the end of the
2. Locate two slotted head Phillips head 8-32 x 3/8 inch screws and two lock
3. Secure the right mount bracket to the end of the inner slide rail using the
4. Tighten the screws and torque to 15 inch-pounds.
5. Repeat steps 1 through 4 to install the left mount bracket onto the second

Attaching the Outer Slide Rails to the HP 9000 Series Rack

Use the following steps to install the outer slide rails in the HP 9000 Series Rack.
Note:
the HP 9000 Series Rack.
Obtain the following items, located in the Rack Mount Kit:
SAN Switch 2/32 Installation Guide
switch; see
Figure
5.
inner rails on the right, power supply end of the switch.
nuts contained in the Rack Mount Kit accessory pouch.
screws and lock nuts.
inner slide rail.
This procedure requires two technicians to properly align the outer slide rails in
Four 3-hole bar nuts
Eight Phillips head 8-32 x 3/8 inch screws
Eight square alignment washers
# 2 Phillips screwdriver with torque capability
"Attaching the Inner Slide Rails to the
Installing the SAN Switch 2/32
Switch," step 1b.
35