HP StorageWorks 2/32 - SAN Switch Installation Manual page 100

San switch 2/32 version 4.0.x installation guide
Hide thumbs Also See for StorageWorks 2/32 - SAN Switch:
Table of Contents

Advertisement

Updating the Core Switch PID Format
11. Issue the switchEnable command. Enable the core switches first, then the
12. Rebuild the device entries for the affected fabric using the cfgmgr
13. If you are not using multi-pathing software, varyon the disk volume groups.
14. If you are not using multi-pathing software, mount all devices again and
15. If you are using multi-pathing software, re-enable the affected path.
16. Repeat for all fabrics.
100
edge switches.
command.
For example:
cfgmgr -v
This command may take several minutes to complete.
The proper usage would be varyonvg <volume_group_name>. For example:
varyonvg datavg
restart I/O. For example,
mount /mnt/jbod