Managing the SAN Switch 2/32
The Fabric OS identifies the power supplies as follows (viewing the switch from
the non-port side):
To determine whether a power supply requires replacing:
Fan Assemblies
The three fan assemblies are hot-swappable if replaced one at a time. The fan
assemblies are identical and fit into any fan assembly slot; see
1
2
Figure 19: Power supplies and fan assemblies locations
Each fan assembly contains two fans, identified by Fabric OS as follows (viewing
the switch from the non-port side assembly on the right contains fans #1 and #2).
76
Power supply #1 is on the right when viewing the switch from the non-port
side.
Power supply #2 is on the left when viewing the switch from the non-port
side.
Check the Power Supply LED next to the AC switch
Enter the psshow command
In Web Tools, click the Power Status icon
1
Power supply #2
Fan assembly containing fans 5,6
The fan assembly in the center contains fans #3 and #4.
The fan assembly on the left contains fans #5 and #6.
2
3
Fan assembly containing fans 3,4
3
Fan assembly containing fans 1,2
4
Power supply #1
5
Figure
4
5
SHR-2580A
SAN Switch 2/32 Installation Guide
19.