Chapter 8
12. Re-install the three power supplies into the HP NetServer.
13. Go to "Attaching the Cable Management Arm" before securing the HP
NetServer in the rack.

Attaching the Cable Management Arm

The Cable Management Arm for the HP NetServer LXr 8500 can only be
mounted on HP Systems racks. The HP NetServer's Cable Management Arm
allows the cables, including the power cord, to move in and out with the HP
NetServer chassis without being accidentally disconnected. See Figure 8-11.
WARNING
Before sliding the HP NetServer out of the rack, ensure the
anti-tip foot is still extended from the front of the rack. A
tip-over hazard exists, so never slide more than one
component out of the rack at a time.
1. Ensure the HP NetServer LXr 8500 is pushed all the way into the rack.
2. At the rear of the HP NetServer, place rack nuts on the left column in the
13th and 18th holes above the baseline of the HP NetServer. See Figure
8-11.
Left
Rear of
Rack
Attach nuts to this face
of the left rear column.
Figure 8-11. Attaching the Rack Nuts to the Left Column
3. Match the inner flange mounting holes with the two threaded inserts in the
rear of the HP NetServer. See Figure 8-12.
Rack Mounting the HP NetServer
"
"
represents
#
#
the EIA unit
numbers on the
rack columns.
#
#
#
#
#
Bottom of
NetServer
Eighteenth Hole
from Bottom
Thirteenth Hole
from Bottom
Sixth Hole
from Bottom
Fourth Hole
from Bottom
101