GS716Tv2 and GS724Tv3 Software Administration Manual
Figure 2-13
Table 2-15. LLDP Configuration Fields
Field
LLDP Properties
TLV Advertised Interval
Hold Multiplier
Reinitializing Delay
Transmit Delay
2. If you make any changes to the page, click Apply to apply the new settings to the system.
LLDP Port Settings
Use the LLDP Port Settings page to specify LLDP parameters that are applied to a specific
interface.
To display the LLDP Port Settings page:
1. Click SystemLLDP Advanced LLDPPort Settings in the navigation tree.
2-24
Description
Specifies the interval at which frames are transmitted. The default is 30
seconds, and the valid range is 1–32768 seconds.
Specifies multiplier on the transmit interval to assign to Time-to-Live
(TTL). The default is 4, and the range is 2–10.
Specifies the delay before a reinitialization. The default is 2 seconds,
and the range is 1–10 seconds.
Specifies the interval for the transmission of notifications. The default is
5 seconds, and the range is 5–3600 seconds.
v1.0, July 2009
Configuring System Information